Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2018 Sep 1;34(9):616-621.
doi: 10.3928/1081597X-20180705-02.

Comparison of Corneal Tomography and a New Combined Tomographic Biomechanical Index in Subclinical Keratoconus

Comparative Study

Comparison of Corneal Tomography and a New Combined Tomographic Biomechanical Index in Subclinical Keratoconus

Tommy C Y Chan et al. J Refract Surg. .

Abstract

Purpose: To investigate and compare the diagnostic ability of corneal tomography and biomechanical and combined parameters for detection of corneal ectasia.

Methods: Consecutive patients with subclinical keratoconus (SCKC) and age-matched controls were included. Only one eye from each patient was selected for analysis. The final D value from the Belin/Ambrósio Enhanced Ectasia Display (BAD) was obtained from the Pentacam (Oculus Optikgeräte, Wetzlar, Germany). The tomographic biomechanical index (TBI) was derived from the Pentacam and Corvis ST (Oculus Optikgeräte). Classification analysis between normal and subclinical keratoconus (SCKC) was evaluated using receiver operating characteristic (ROC) curves. The area under the ROC curve (AUC) and partial AUC (pAUC) with specificity of 80% or greater were compared.

Results: Twenty-three eyes with SCKC and 37 normal eyes were included. All Pentacam-derived parameters (P < .001) and all but two Corvis ST-derived parameters (P < .020) were significantly different between normal and SCKC eyes. A significant difference was found in the final D value (P ≤ .020) and TBI (P ≤ .040) between normal and SCKC eyes. For differentiating normal and SCKC eyes, TBI and BAD final D value demonstrated the highest AUC (0.925 and 0.786, respectively) and pAUC (0.150 and 0.088, respectively). TBI demonstrated 84.4% sensitivity and 82.4% specificity using a cut-off of 0.16. Comparative analysis between these parameters showed that AUC and pAUC of TBI were significantly higher than all parameters from Pentacam (P ≤ .032).

Conclusions: In the current study, combined use of tomographic and biomechanical parameters demonstrated a higher capability in differentiating normal and SCKC eyes when compared to tomographic analysis alone. [J Refract Surg. 2018;34(9):616-621.].

PubMed Disclaimer

Similar articles

Cited by

Publication types

MeSH terms

LinkOut - more resources