Ultrasound assessment of the prevalence of increased gastric contents and volume in elective pediatric patients: A prospective cohort study
- PMID: 30207013
- DOI: 10.1111/pan.13472
Ultrasound assessment of the prevalence of increased gastric contents and volume in elective pediatric patients: A prospective cohort study
Abstract
Background: Though pulmonary aspiration of gastric contents occurs mainly in the setting of emergency surgery, it may also occur in children scheduled for elective surgery without any obvious clinical risk factor. Increased gastric content volume is one the predisposing factors for pulmonary aspiration that could affect such children and may be identified using ultrasound examination of the gastric antrum.
Aims: We aimed to assess the prevalence of "at-risk stomach" defined by ultrasound visualization of any solid content in the antrum and/or by calculated gastric fluid volume > 1.25 mL/kg, in children scheduled for elective surgery.
Methods: Children scheduled for elective surgery were consecutively included into this prospective cohort study. Preoperative ultrasound examination of the antrum was performed in both the supine and the right lateral decubitus positions. Gastric fluid content was assessed using a 0-2 qualitative grading scale. The antral cross-sectional area was also measured in both the supine and the right lateral decubitus positions, allowing the calculation of the gastric fluid volume according to a formula previously described.
Results: We analyzed 200 elective children. Median duration of fasting was 4 hours for liquids and >13 hours for solids. None of the children included in this study had evidence of solid content. Six (3%) children had a Grade 2 antrum (fluid content seen in both the supine and the right lateral decubitus positions). Two children had a gastric fluid volume >1.25 mL/kg. The prevalence of "at-risk stomach" was 1% (95% confidence interval: 0.2%-3.9%).
Conclusion: According to our results, only 1% of elective children had potentially increased risk for pulmonary aspiration. Further studies should be performed in order to define the target population of elective children for which ultrasound assessment of gastric content should be performed prior to general anesthesia.
Keywords: child; general anesthesia; measurement; ultrasound.
© 2018 John Wiley & Sons Ltd.
Comment in
-
Can we use ultrasound examination of gastric content as a diagnostic test in clinical anaesthesia?Paediatr Anaesth. 2019 Feb;29(2):112-113. doi: 10.1111/pan.13555. Paediatr Anaesth. 2019. PMID: 30724017 No abstract available.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources