Radiation Dose Reduction at Pediatric CT: Use of Low Tube Voltage and Iterative Reconstruction
- PMID: 30207943
- DOI: 10.1148/rg.2018180041
Radiation Dose Reduction at Pediatric CT: Use of Low Tube Voltage and Iterative Reconstruction
Erratum in
-
Radiation Dose Reduction at Pediatric CT: Use of Low Tube Voltage and Iterative Reconstruction-Erratum.Radiographics. 2019 May-Jun;39(3):912. doi: 10.1148/rg.2019194005. Radiographics. 2019. PMID: 31059408 No abstract available.
Abstract
Given the growing awareness of and concern for potential carcinogenic effects of exposure of children to ionizing radiation at CT, optimizing acquisition parameters is crucial to achieve diagnostically acceptable image quality at the lowest possible radiation dose. Among currently available dose reduction techniques, recent technical innovations have allowed the implementation of low tube voltage scans and iterative reconstruction (IR) techniques into daily clinical practice for pediatric CT. The benefits of lowering tube voltage include a considerable reduction in radiation dose and improved contrast on images, especially when an iodinated contrast medium is used. The increase in noise, which is attributed to decreased photon penetration, is a major drawback but is not as severe as that at adult CT because of the small body size of children. In addition, use of IR algorithms can suppress increased noise, yielding wider applicability for low tube voltage scans. However, a careful implementation strategy and methodologic approach are necessary to maximize the potential for dose reduction while preserving diagnostic image quality under each clinical condition. The potential pitfalls of and topics related to these techniques include (a) the effect of tube voltage on the surface radiation dose, (b) the effect of window settings, (c) accentuation of metallic artifacts, (d) deterioration of low contrast detectability at low-dose settings, (e) interscanner variation of x-ray spectra, and (f) a comparison with the use of a spectral shaping technique. Appropriate use of low tube voltage and IR techniques is helpful for radiation dose reduction in most applications of pediatric CT. Online DICOM image stacks are available for this article . ©RSNA, 2018.
Comment in
-
Invited Commentary on "Radiation Dose Reduction in Pediatric CT," with Response from Dr Nagayama et al.Radiographics. 2018 Sep-Oct;38(5):1440-1442. doi: 10.1148/rg.2018180193. Radiographics. 2018. PMID: 30207941 No abstract available.
Similar articles
-
Successful Dose Reduction Using Reduced Tube Voltage With Hybrid Iterative Reconstruction in Pediatric Abdominal CT.AJR Am J Roentgenol. 2015 Aug;205(2):392-9. doi: 10.2214/AJR.14.12698. AJR Am J Roentgenol. 2015. PMID: 26204293
-
Reducing CT radiation dose with iterative reconstruction algorithms: the influence of scan and reconstruction parameters on image quality and CTDIvol.Eur J Radiol. 2014 Sep;83(9):1645-54. doi: 10.1016/j.ejrad.2014.05.033. Epub 2014 Jun 5. Eur J Radiol. 2014. PMID: 25037931
-
CT of the Abdomen with Reduced Tube Voltage in Adults: A Practical Approach.Radiographics. 2015 Nov-Dec;35(7):1922-39. doi: 10.1148/rg.2015150048. Epub 2015 Oct 16. Radiographics. 2015. PMID: 26473536 Review.
-
Improvement of image quality at low-radiation dose and low-contrast material dose abdominal CT in patients with cirrhosis: intraindividual comparison of low tube voltage with iterative reconstruction algorithm and standard tube voltage.J Comput Assist Tomogr. 2012 Jul-Aug;36(4):495-501. doi: 10.1097/RCT.0b013e31825b821f. J Comput Assist Tomogr. 2012. PMID: 22805682
-
Basics of iterative reconstruction methods in computed tomography: A vendor-independent overview.Eur J Radiol. 2018 Dec;109:147-154. doi: 10.1016/j.ejrad.2018.10.025. Epub 2018 Oct 26. Eur J Radiol. 2018. PMID: 30527298 Review.
Cited by
-
Validation of computed tomography angiography as a complementary test in the assessment of renal artery stenosis: a comparison with digital subtraction angiography.Pediatr Radiol. 2021 Dec;51(13):2507-2520. doi: 10.1007/s00247-021-05145-1. Epub 2021 Aug 10. Pediatr Radiol. 2021. PMID: 34374838
-
Recovering Image Quality in Low-Dose Pediatric Renal Scintigraphy Using Deep Learning.J Imaging. 2025 Mar 19;11(3):88. doi: 10.3390/jimaging11030088. J Imaging. 2025. PMID: 40137200 Free PMC article.
-
Low Dose Pediatric CT Head Protocol using Iterative Reconstruction Techniques: A Comparison with Standard Dose Protocol.Clin Neuroradiol. 2024 Mar;34(1):229-239. doi: 10.1007/s00062-023-01361-4. Epub 2023 Nov 28. Clin Neuroradiol. 2024. PMID: 38015280
-
Assessment of low-dose paranasal sinus CT imaging using a new deep learning image reconstruction technique in children compared to adaptive statistical iterative reconstruction V (ASiR-V).BMC Med Imaging. 2022 Jun 3;22(1):106. doi: 10.1186/s12880-022-00834-1. BMC Med Imaging. 2022. PMID: 35658908 Free PMC article.
-
Quantitative and qualitative assessment of ultra-low-dose paranasal sinus CT using deep learning image reconstruction: a comparison with hybrid iterative reconstruction.Eur Radiol. 2025 Jun 13. doi: 10.1007/s00330-025-11763-2. Online ahead of print. Eur Radiol. 2025. PMID: 40514598
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical