Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2019 Mar;29(3):1400-1407.
doi: 10.1007/s00330-018-5724-4. Epub 2018 Sep 12.

Comparison of full-iodine conventional CT and half-iodine virtual monochromatic imaging: advantages and disadvantages

Affiliations
Comparative Study

Comparison of full-iodine conventional CT and half-iodine virtual monochromatic imaging: advantages and disadvantages

Haruto Sugawara et al. Eur Radiol. 2019 Mar.

Abstract

Purpose: To compare image quality of abdominal arteries between full-iodine-dose conventional CT and half-iodine-dose virtual monochromatic imaging (VMI).

Materials and methods: We retrospectively evaluated images of 21 patients (10 men, 11 women; mean age, 73.9 years) who underwent both full-iodine (600 mg/kg) conventional CT and half-iodine (300 mg/kg) VMI. For each patient, we measured and compared CT attenuation and the contrast-to-noise ratio (CNR) of the aorta, celiac artery, and superior mesenteric artery (SMA). We also compared CT dose index (CTDI). Two board-certified diagnostic radiologists evaluated visualisation of the main trunks and branches of the celiac artery and SMA in maximum-intensity-projection images. We evaluated spatial resolution of the two scans using an acrylic phantom.

Results: The two scans demonstrated no significant difference in CT attenuation of the aorta, celiac artery, and SMA, but CNRs of the aorta and celiac artery were significantly higher in VMI (p = 0.011 and 0.030, respectively). CTDI was significantly higher in VMI (p = 0.024). There was no significant difference in visualisation of the main trunk of the celiac artery and SMA, but visualisation of the gastroduodenal artery, pancreatic arcade, branch of the SMA, marginal arteries, and vasa recta was significantly better in the conventional scan (p < 0.001). The calculated modular transfer function (MTF) suggested decreased spatial resolution of the half-iodine VMI.

Conclusion: Large-vessel depiction and CNRs were comparable between full-iodine conventional CT and half-iodine VMI images, but VMI did not permit clear visualisation of small arteries and required a larger radiation dose.

Key points: ・Reducing the dose of iodine contrast medium is essential for chronic kidney disease patients to prevent contrast-induced nephropathy. ・In virtual monochromatic images at low keV, contrast of relatively large vessels is maintained even with reduced iodine load, but visibility of small vessels is impaired with decreased spatial resolution. ・We should be aware about the advantages and disadvantages associated with virtual monochromatic imaging with reduced iodine dose.

Keywords: CT angiography; Iodine; Qualitative evaluation; Quantitative evaluation; Retrospective study.

PubMed Disclaimer

References

    1. Radiographics. 2004 Sep-Oct;24(5):1367-80 - PubMed
    1. Eur Radiol. 2012 Dec;22(12):2654-61 - PubMed
    1. Radiology. 2012 Jan;262(1):109-16 - PubMed
    1. J Comput Assist Tomogr. 2016 Sep-Oct;40(5):777-83 - PubMed
    1. Acad Radiol. 2018 Apr;25(4):509-518 - PubMed

Publication types

LinkOut - more resources