Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2019 Feb;43(2):125-131.
doi: 10.1111/aor.13319. Epub 2018 Sep 14.

Increased Plasma-Free Hemoglobin Levels Identify Hemolysis in Patients With Cardiogenic Shock and a Trans valvular Micro-Axial Flow Pump

Affiliations

Increased Plasma-Free Hemoglobin Levels Identify Hemolysis in Patients With Cardiogenic Shock and a Trans valvular Micro-Axial Flow Pump

Michele L Esposito et al. Artif Organs. 2019 Feb.

Abstract

Hemolysis is a potential limitation of percutaneously delivered left-sided mechanical circulatory support pumps, including trans valvular micro-axial flow pumps (TVP). Hemolytic biomarkers among durable left ventricular assist devices include lactate dehydrogenase (LDH) >2.5 times the upper limit of normal (ULN) and plasma-free hemoglobin (pf-Hb) >20 mg/dL. We examined the predictive value of these markers among patients with cardiogenic shock (CS) receiving a TVP. We retrospectively studied records of 116 consecutive patients receiving an Impella TVP at our institution between 2012 and 2017 for CS. Twenty-three met inclusion/exclusion criteria, and had sufficient pf-Hb data for analysis. Area under receiver-operator characteristic (ROC) curve for diagnosing hemolysis were calculated. Mean age was 62 ± 14 years and ejection fraction was 15 ± 5%. Mean duration of support was 5.4 ± 3.5 days. Pre-device LDH levels were >2.5x ULN in 71% (n = 5/7) of 5.0 and 29% of CP patients, while pre-device pf-Hb levels were >20 mg/dL in 14% (n = 1/7) of 5.0 and 25% (n = 4/16) of CP patients. Given elevated baseline LDH and pf-Hb levels, we defined hemolysis as a pf-Hb level >40 mg/dL within 72 h post-implant plus clinical evidence of device-related hemolysis. We identified that 30% (n = 7/23) had device-related hemolysis. Using ROC curve-derived cut-points, an increase in delta pf-Hb by >27mg/dL, not delta LDH, within 24 h after TVP implant (delta pf-Hb: C-statistic = 0.79, sensitivity: 57%, specificity: 93%, p <0.05) was highly predictive of hemolysis. In conclusion, we identified a change in pf-Hb, not LDH, levels is highly sensitive and specific for hemolysis in patients treated with a TVP for CS.

Keywords: Cardiogenic shock; Circulatory support; Hemolysis; Ventricular assist device.

PubMed Disclaimer

LinkOut - more resources