Endoscopic laser treatment. II. Comparison of the efficacy of high and low power photocoagulation in control of severely bleeding experimental ulcers in dogs
- PMID: 302231
Endoscopic laser treatment. II. Comparison of the efficacy of high and low power photocoagulation in control of severely bleeding experimental ulcers in dogs
Abstract
The coagulative efficacy of a "high power" argon laser which delivers 6.5 +/- 1.0 w was compared to that of a "low power" argon laser which delivers 1.0 +/- 0.1 w. The wave-guide angle of divergence was 8 degrees. For the high power laser, the distance between the wave-guide tip and the mucosa varied from 1.0 to 1.5 cm with a delivered power density range of 160 to 487 w per cm2. For the low power laser, the distance between the tip and mucosa varied from 0.7 to 1.3 cm with a power density of 35 to 146 w per cm2. Group A consisted of acute experiments in 6 heparinized dogs in which 51 standard-sized acute gastric ulcers extending into the submucosa were made at laparotomy via a large gastrotomy. Ulcer bleeding rates were quantified into three categories of severity. Within each category, ulcers were randomized to high power, low power, or untreated control. All 19 low power-treated ulcers and 16 untreated controls continued bleeding; 13 of 16 high power-treated ulcers stopped bleeding completely. Representative ulcers were examined histologically. Group B consisted of chronic experiments on 31 ulcers in 7 unheparinized dogs. These ulcers were either treated with high power or left as untreated controls. Dogs were killed and the ulcers were examined histologically at 7, 14, and 28 days. Only rarely did the laser injury penetrate into the muscularis externa. There were no perforations. By 14 days, all lesions were covered with normal surface epithelium. These data encourage further development of congruent to 7.0 w argon laser photocoagulation for eventual clinical use in man.
Similar articles
-
High power argon laser treatment via standard endoscopes. I. A preliminary study of efficacy in control of experimental erosive bleeding.Gastroenterology. 1976 Oct;71(4):558-63. Gastroenterology. 1976. PMID: 1085268
-
Argon vs. neodymium YAG laser photocoagulation of experimental canine gastric ulcers.Gastroenterology. 1979 Sep;77(3):491-6. Gastroenterology. 1979. PMID: 572314
-
Comparison of argon laser photocoagulation and bipolar electrocoagulation for endoscopic hemostasis in the canine colon.Gastroenterology. 1982 Oct;83(4):830-5. Gastroenterology. 1982. PMID: 7049825
-
Laser photocoagulation for gastrointestinal bleeding.Clin Gastroenterol. 1978 Sep;7(3):765-74. Clin Gastroenterol. 1978. PMID: 361312 Review.
-
Endoscopic control of upper gastrointestinal bleeding.Can J Surg. 1985 Jul;28(4):305-8. Can J Surg. 1985. PMID: 3893665 Review.
Cited by
-
Laser photocoagulation in alimentary bleeding.World J Surg. 1983 Nov;7(6):710-8. doi: 10.1007/BF01655210. World J Surg. 1983. PMID: 6362213 Review. No abstract available.
-
Failure of cyanoacrylate tissue glue (Flucrylate, MBR4197) to stop bleeding from experimental canine gastric ulcers.Am J Dig Dis. 1978 Oct;23(10):903-8. doi: 10.1007/BF01072464. Am J Dig Dis. 1978. PMID: 362902
-
Endoscopic hemostasis using laser photocoagulation and electrocoagulation.Dig Dis Sci. 1981 Jul;26(7 Suppl):31S-40S. doi: 10.1007/BF01300804. Dig Dis Sci. 1981. PMID: 6821288 Review. No abstract available.
-
Comparative study of the effects of argon and neodymium YAG laser beams on the normal fundic wall in the beagle dog.Dig Dis Sci. 1982 May;27(5):425-33. doi: 10.1007/BF01295651. Dig Dis Sci. 1982. PMID: 7075429
-
Safety and efficacy of Neodymium-Yag laser photocoagulation: an experimental study in dogs.Gut. 1981 Jan;22(1):38-44. doi: 10.1136/gut.22.1.38. Gut. 1981. PMID: 7193164 Free PMC article.