Reliability of scapular kinematics estimated with three-dimensional motion analysis during shoulder elevation and flexion
- PMID: 30223210
- DOI: 10.1016/j.gaitpost.2018.09.008
Reliability of scapular kinematics estimated with three-dimensional motion analysis during shoulder elevation and flexion
Abstract
Background: Knowing the reliability of three-dimensional motion analysis to evaluate scapular kinematics during upper limb movements is essential to plan further research dedicated to understanding scapulothoracic joint movements relative to the global shoulder motion.
Research question: The aim of this study was to assess the intra-subject as well as intra- and interrater reliability of scapulothoracic joint angles during shoulder elevation in scapular plane and shoulder flexion.
Methods: Twenty healthy participants (26.6 ± 3.5 years) were asked to perform maximum shoulder elevation in scapular plane as well as shoulder flexion. Reliability was assessed using the intraclass correlation coefficient (ICC) and its 95% confidence interval of scapular kinematics (rotation, tilting, pro-retraction) at each degree of global motion (shoulder elevation or shoulder flexion) between 0° to 150°.
Results: ICCs above 0.60 were accepted as good indicators for reliability. Intra-subject reliability was found to be very high (>0.9 for most part) for all scapulothoracic joint angles during both movements. Intra- and interrater reliability also showed good reliability being above 0.60 for the most part (except scapula tilting during shoulder elevation). Scapular kinematics showed low reliability during the respective first 10° and 20° of shoulder elevation and shoulder flexion. Furthermore, decreasing reliability was found above 120° of shoulder elevation or flexion.
Significance: This study generally showed good to high levels of reliability in the range of interest (20-120°) in evaluating scapula kinematics in healthy adults during shoulder elevation and flexion; these results are important for future research providing a better understanding of scapular kinematics.
Keywords: Glenohumeral joint; Kinematics; Scapulothoracic angles; Shoulder.
Copyright © 2018 Elsevier B.V. All rights reserved.
Similar articles
-
How Do Scapulothoracic Kinematics During Shoulder Elevation Differ Between Adults With and Without Rotator Cuff Arthropathy?Clin Orthop Relat Res. 2020 Nov;478(11):2640-2649. doi: 10.1097/CORR.0000000000001406. Clin Orthop Relat Res. 2020. PMID: 32694316 Free PMC article.
-
Three-Dimensional Scapular Kinematics in Patients with Reverse Total Shoulder Arthroplasty during Arm Motion.Clin Orthop Surg. 2016 Sep;8(3):316-24. doi: 10.4055/cios.2016.8.3.316. Epub 2016 Aug 10. Clin Orthop Surg. 2016. PMID: 27583116 Free PMC article.
-
Verification of acromion marker cluster and scapula spinal marker cluster methods for tracking shoulder kinematics: a comparative study with upright four-dimensional computed tomography.BMC Musculoskelet Disord. 2024 Jul 26;25(1):589. doi: 10.1186/s12891-024-07717-2. BMC Musculoskelet Disord. 2024. PMID: 39060988 Free PMC article.
-
The Scapula: The Greater Masquerader of Shoulder Pathologies.Instr Course Lect. 2024;73:587-607. Instr Course Lect. 2024. PMID: 38090927 Review.
-
Shoulder kinematics impact subacromial proximities: a review of the literature.Braz J Phys Ther. 2020 May-Jun;24(3):219-230. doi: 10.1016/j.bjpt.2019.07.009. Epub 2019 Jul 24. Braz J Phys Ther. 2020. PMID: 31377124 Free PMC article. Review.
Cited by
-
Comparison of Shoulder Range of Motion Quantified with Mobile Phone Video-Based Skeletal Tracking and 3D Motion Capture-Preliminary Study.Sensors (Basel). 2024 Jan 15;24(2):534. doi: 10.3390/s24020534. Sensors (Basel). 2024. PMID: 38257626 Free PMC article.
-
How Do Scapulothoracic Kinematics During Shoulder Elevation Differ Between Adults With and Without Rotator Cuff Arthropathy?Clin Orthop Relat Res. 2020 Nov;478(11):2640-2649. doi: 10.1097/CORR.0000000000001406. Clin Orthop Relat Res. 2020. PMID: 32694316 Free PMC article.
-
Three-dimensional measurements of scapular kinematics: Interrater reliability and validation of a skin marker-based model against an intracortical pin model.Heliyon. 2024 Apr 9;10(8):e29414. doi: 10.1016/j.heliyon.2024.e29414. eCollection 2024 Apr 30. Heliyon. 2024. PMID: 38644878 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources