Objectives: To evaluate the effect of a spiral tube on contrast enhancement in the hepatic arterial phase (HAP) of gadoxetic acid (Gd-EOB-DTPA)-enhanced magnetic resonance imaging (MRI).
Methods: In this retrospective study, we observed 104 patients who underwent dynamic MRI of the liver between October 2017 and December 2017. Three Gd-EOB-DTPA injection protocols were compared: (A) conventional method (undiluted Gd-EOB-DTPA, injection rate 1 ml/s, n = 36); (B) spiral dilution method (1:1 diluted Gd-EOB-DTPA with saline [off-label], injection rate 2 ml/s via spiral tube, n = 38); (C) spiral-flushed method (undiluted Gd-EOB-DTPA, injection rate 1 ml/s via spiral tube, n = 30). We regarded protocol-A as a control. The signal-to-noise ratio (SNR) of the abdominal aorta was calculated using arterial phase images. Image contrast and artefacts were evaluated by two board-certified radiologists, using a four-point scale. Statistical analyses included Dunnett's test, the Kruskal-Wallis test and the Steel test.
Results: The SNR of the aorta was significantly higher with protocol-C (25.4 ± 8.8) than protocol-A (20.8 ± 5.4, p = 0.01). There was no significant difference in SNR between protocols A and B (p = 0.47). The contrast score of protocol-C was significantly higher than that of protocol-A (p = 0.0019). There was no significant difference in contrast score between protocols A and B (p = 0.50). There was no significant difference in artefacts among the three protocols (p = 0.96).
Conclusions: Use of a spiral tube with a slow injection protocol contributed to improved aortic contrast enhancement in the HAP of GD-EOB-DTPA-enhanced hepatic MRI.
Key points: • Gadoxetic acid shows weaker arterial enhancement at recommended doses, compared with nonspecific gadolinium agents; selection of an appropriate injection protocol is important. • A spiral flow-generating tube improves the transport efficiency of the contrast media, and increases the signal-to-noise ratio of the aorta in hepatic arterial phase. • A spiral flow-generating tube does not contribute to artefact reduction in hepatic arterial phase.
Keywords: Contrast media; Liver; Magnetic resonance imaging.
Similar articles
-
Radial volumetric imaging breath-hold examination (VIBE) with k-space weighted image contrast (KWIC) for dynamic gadoxetic acid (Gd-EOB-DTPA)-enhanced MRI of the liver: advantages over Cartesian VIBE in the arterial phase.Eur Radiol. 2014 Jun;24(6):1290-9. doi: 10.1007/s00330-014-3122-0. Epub 2014 Mar 15. Eur Radiol. 2014. PMID: 24633374
-
Timing of the hepatic arterial phase at Gd-EOB-DTPA-enhanced hepatic dynamic MRI: comparison of the test-injection and the fixed-time delay method.J Magn Reson Imaging. 2013 Sep;38(3):548-54. doi: 10.1002/jmri.24017. Epub 2013 Jun 6. J Magn Reson Imaging. 2013. PMID: 23744782 Clinical Trial.
-
Vascular enhancement in early dynamic liver MR imaging in an animal model: comparison of two injection regimen and two different doses Gd-EOB-DTPA (gadoxetic acid) with standard Gd-DTPA.Invest Radiol. 2009 Jun;44(6):305-10. doi: 10.1097/rli.0b013e3181a24512. Invest Radiol. 2009. PMID: 19462484
-
Consensus statements from a multidisciplinary expert panel on the utilization and application of a liver-specific MRI contrast agent (gadoxetic acid).AJR Am J Roentgenol. 2015 Mar;204(3):498-509. doi: 10.2214/AJR.13.12399. AJR Am J Roentgenol. 2015. PMID: 25714278
-
A pictorial review of brain arterial spin labelling artefacts and their potential remedies in clinical studies.Neuroradiol J. 2021 Jun;34(3):154-168. doi: 10.1177/1971400920977031. Epub 2020 Dec 7. Neuroradiol J. 2021. PMID: 33283653 Free PMC article. Review.
Cited by
-
Influence of dilution on arterial-phase artifacts and signal intensity on gadoxetic acid-enhanced liver MRI.Eur Radiol. 2023 Jan;33(1):523-534. doi: 10.1007/s00330-022-08984-0. Epub 2022 Jul 27. Eur Radiol. 2023. PMID: 35895119 Free PMC article.
References
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical