Arterio-venous blood gas Δvalues for validation of umbilical cord blood samples at birth are not only biased by sample mix ups but also affected by clinical factors
- PMID: 30256382
- DOI: 10.1111/aogs.13471
Arterio-venous blood gas Δvalues for validation of umbilical cord blood samples at birth are not only biased by sample mix ups but also affected by clinical factors
Abstract
Introduction: Traditional validation of umbilical cord blood samples with positive veno-arterial ΔpH and arterio-venous ΔpCO2 values confirms the source of samples, whereas negative Δvalues represent mix-up of samples. To investigate whether this is true, the distributions of V-A ΔpO2 and A-V Δlactate were also explored and related to clinical characteristics. In addition, different cord blood sampling techniques were evaluated.
Material and methods: Register study with cord blood acid-base and clinical data from 27 233 newborns. Clinical characteristics were related to positive, zero and negative Δvalues. Blood samplings from unclamped and double-clamped cords were compared. A two-sided P < 0.05 was considered significant.
Results: ΔpH and ΔpCO2 values distributed into positive, around zero, and negative sub-populations, with significant differences in pH and clinical characteristics between sub-populations. No such sub-populations were distinguished for ΔpO2 and Δlactate. The 2.5th and 5th ΔpH percentiles were 0.013 and 0.022, respectively, and for ΔpCO2 0.30 and 0.53 kPa. Applying 5th percentile criteria resulted in 3.5% of "approved" cases showing a ΔpO2 ≤ 0. Puncture and sampling of the unclamped cord resulted in significantly better sample quality.
Conclusions: Unphysiological negative ΔpO2 values occurred despite correct validation with traditional criteria. Δlactate cannot be used for validation because both positive and negative values are physiological. Positive/around zero/negative ΔpH and ΔpCO2 sub-populations were associated with significant differences in pH and clinical characteristics, indicating that defective sampling and sample handling are not the sole explanations for negative Δvalues. Prompt puncture and sampling of the unclamped cord resulted in best sample quality.
Keywords: pCO 2; pO 2; blood gases; delayed sampling; lactate; pH; pregnancy; umbilical cord; validation.
© 2018 Nordic Federation of Societies of Obstetrics and Gynecology.
Similar articles
-
Effect of delayed sampling on umbilical cord arterial and venous lactate and blood gases in clamped and unclamped vessels.Arch Dis Child Fetal Neonatal Ed. 2006 Sep;91(5):F342-5. doi: 10.1136/adc.2005.086744. Epub 2006 Apr 25. Arch Dis Child Fetal Neonatal Ed. 2006. PMID: 16638782 Free PMC article.
-
Is the sampling site along the umbilical artery significant?Gynecol Obstet Invest. 2002;54(3):172-5. doi: 10.1159/000067887. Gynecol Obstet Invest. 2002. PMID: 12571441
-
Delayed umbilical cord clamping at birth has effects on arterial and venous blood gases and lactate concentrations.BJOG. 2008 May;115(6):697-703. doi: 10.1111/j.1471-0528.2008.01708.x. BJOG. 2008. PMID: 18410652
-
Umbilical cord blood gas analysis.Obstet Gynecol Clin North Am. 1999 Dec;26(4):695-709. doi: 10.1016/s0889-8545(05)70107-8. Obstet Gynecol Clin North Am. 1999. PMID: 10587963 Review.
-
Collecting and analyzing cord blood gases.Clin Obstet Gynecol. 1993 Mar;36(1):13-23. doi: 10.1097/00003081-199303000-00005. Clin Obstet Gynecol. 1993. PMID: 7679616 Review.
Cited by
-
Adverse neonatal outcome and veno-arterial differences in umbilical cord blood pH (ΔpH) at birth: a population-based study of 108,629 newborns.BMC Pregnancy Childbirth. 2023 Mar 11;23(1):162. doi: 10.1186/s12884-023-05487-8. BMC Pregnancy Childbirth. 2023. PMID: 36906543 Free PMC article.
Publication types
MeSH terms
Substances
Grants and funding
LinkOut - more resources
Full Text Sources
Other Literature Sources