Short-term outcome and mid-term access site complications of the percutaneous approach to endovascular abdominal aortic aneurysm repair (PEVAR) after introduction in a vascular teaching hospital
Abstract
The objective is to evaluate our center's experience with the safety and efficacy of the percutaneous approach to endovascular abdominal aortic aneurysm repair (PEVAR) with use of the Perclose Proglide device, in the first period after introduction in our center in 2014. We retrospectively identified all patients that underwent PEVAR or endograft extension with percutaneous approach in our center in the urgent and elective setting. Included were all procedures performed between the introduction of the technique in January 2014 and February 2016 when PEVAR had become the predominant technique in our center. Exclusion progressed from expected difficulty of the procedure as estimated by the operator to total calcification of the ventral wall of the CFA towards the end of the study period. Surgical and clinical reports were used to analyze patient characteristics, procedural success, and short-term outcome after 30 days. Follow-up imaging was used to assess mid-term access site complications at 1 and 2 years postoperatively. A univariate regression analysis was conducted to determine significant predictors of access-related complications with the Perlcose Proglide system. Of all 78 patients (mean age 74, SD: 7 years, 70 men), 68 (87.2%) underwent PEVAR and 10 (12.8%) underwent endograft extension procedures with percutaneous approach. Sixty-seven (85.9%) patients underwent an elective procedure and 11 (14.1%) patients underwent urgent PEVAR. The total number of vessels that was percutaneously accessed was 142. Direct technical success of the procedure as analyzed per vessel was 98.6% (140/142), with two cases of conversion to the femoral cut-down approach. A total of 274 Perclose Proglide devices were placed. Device failure of the Perclose device occurred in 5.8% (16/274) and was reason for conversion to cut-down procedure in one case. Mean duration of the procedure and median time of hospitalization were 100 (SD: 34) min and 2 (IQR 1, 3) days, respectively. Event-free survival per vessel after 30 days was 91.0%, with two minor access-related complication. Fifty-five individual patients (105 vessels) were eligible for inclusion in the 1-year follow-up analysis. Of these patients, 19 (34 vessels) could be included in the 2-year follow-up analysis. No additional access site complications occurred at mid-term follow-up. No significant predictors of device failure were found. The percutaneous approach to EVAR appears to be a safe and effective option with high success rate and low complication rate in a real-world setting. Based on our findings, we conclude that the technique can safely be introduced in a vascular center.
Keywords: Abdominal aortic aneurysm; Endovascular aneurysm repair; Vascular closure devices.
Similar articles
-
A multicenter, randomized, controlled trial of totally percutaneous access versus open femoral exposure for endovascular aortic aneurysm repair (the PEVAR trial).J Vasc Surg. 2014 May;59(5):1181-93. doi: 10.1016/j.jvs.2013.10.101. Epub 2014 Jan 17. J Vasc Surg. 2014. PMID: 24440678 Clinical Trial.
-
Safety and utility of total percutaneous endovascular aortic repair with a single Perclose ProGlide closure device.J Vasc Surg. 2016 Mar;63(3):585-8. doi: 10.1016/j.jvs.2015.08.111. Epub 2015 Oct 23. J Vasc Surg. 2016. PMID: 26506938
-
Safety and effectiveness of total percutaneous access for fenestrated endovascular aortic aneurysm repair.J Vasc Surg. 2016 Oct;64(4):896-901. doi: 10.1016/j.jvs.2016.03.444. Epub 2016 May 27. J Vasc Surg. 2016. PMID: 27237404
-
Percutaneous Endovascular Aortic Aneurysm Repair for Abdominal Aortic Aneurysm.Curr Cardiol Rep. 2018 Jul 26;20(9):79. doi: 10.1007/s11886-018-1023-6. Curr Cardiol Rep. 2018. PMID: 30046990 Review.
-
Financial Impact of PEVAR Compared With Standard Endovascular Repair in Canadian Hospitals.Can Assoc Radiol J. 2018 May;69(2):215-219. doi: 10.1016/j.carj.2017.08.003. Epub 2018 Feb 1. Can Assoc Radiol J. 2018. PMID: 29395253 Review.
Cited by
-
Investigating the effects of percutaneous endovascular aneurysm repair for abdominal aortic aneurysm on the lumen size of the common femoral artery.CVIR Endovasc. 2024 Sep 10;7(1):66. doi: 10.1186/s42155-024-00476-0. CVIR Endovasc. 2024. PMID: 39254910 Free PMC article.
-
Accuracy and feasibility in building a personalized 3D printed femoral pseudoaneurysm model for endovascular training.PLoS One. 2024 Jun 3;19(6):e0304506. doi: 10.1371/journal.pone.0304506. eCollection 2024. PLoS One. 2024. PMID: 38829913 Free PMC article.
-
Dual Suture Versus Suture and Plug Closure Devices for Large Bore Access Haemostasis During Percutaneous Access Endovascular Aneurysm Repair.Cardiovasc Intervent Radiol. 2023 Nov;46(11):1553-1561. doi: 10.1007/s00270-023-03570-3. Epub 2023 Oct 12. Cardiovasc Intervent Radiol. 2023. PMID: 37828234
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical