Multicenter Study
. 2019 Apr;11(4):396-399.
doi: 10.1136/neurintsurg-2018-014204. Epub 2018 Sep 27.

Treatment of intracranial aneurysms using the pipeline flex embolization device with shield technology: angiographic and safety outcomes at 1-year follow-up

Affiliations
Multicenter Study

Treatment of intracranial aneurysms using the pipeline flex embolization device with shield technology: angiographic and safety outcomes at 1-year follow-up

Mario Martínez-Galdámez et al. J Neurointerv Surg. 2019 Apr.

Abstract

Purpose: The Pipeline Embolization Device (PED) is a routine first-line treatment option for intracranial aneurysms (IAs). The Pipeline Flex Embolization Device with Shield Technology (Pipeline Shield) is an updated version of the PED which has been modified to include a surface phosphorylcholine biocompatible polymer. Its early technical success and safety have been reported previously. Here, we assessed the long-term safety and efficacy of the Pipeline Shield for the treatment of IAs.

Materials and methods: The Pipeline Flex Embolization Device with Shield Technology (PFLEX) study was a prospective, single-arm, multicenter study for the treatment of unruptured IAs using the Pipeline Shield. The primary endpoint was a major stroke in the territory supplied by the treated artery or neurologic death at 1-year post-procedure. Angiographic outcomes were also assessed by an independent radiology laboratory at 6 months and 1 year.

Results: Fifty patients (mean age, 53 years; 82% female) with 50 unruptured IAs were treated. Mean aneurysm diameter was 8.82±6.15 mm. Of the target aneurysms, 38/50 (76%) were small (<10 mm), 11/50 (22%) were large (≥10 and<25 mm), and 1/50 (2%) was giant (≥25 mm). Forty-seven (94%) were located in the internal carotid artery and three (6%) in the vertebral artery. At 1-year post-procedure, no major strokes or neurologic deaths were reported, and complete occlusion was achieved in 27/33 (81.8%). There were no instances of aneurysm recurrence or retreatment.

Conclusions: Our 1-year follow-up concerning angiographic and safety outcomes corroborate previous evidence that the Pipeline Shield is a safe and effective treatment for IAs.

Trial registration number: NCT02390037.

Keywords: intracranial aneurysm; phosphorylcholine; pipeline embolization device.

PubMed Disclaimer

Conflict of interest statement

Competing interests: MM-G serves as a proctor and consultant for Medtronic. SML proctors and consults for Medtronic. TL previously consulted and proctored for Covidien, Stryker, and MicroVention, and currently serves as a proctor and consultant for Sequent Medical. EPB receives honoraria from Medtronic and serves as a consultant for Medtronic.

References

    1. Jiang B, Paff M, Colby GP, et al. . Cerebral aneurysm treatment: modern neurovascular techniques. Stroke Vasc Neurol 2016;1:93–100. 10.1136/svn-2016-000027 - DOI - PMC - PubMed
    1. Kallmes DF, Brinjikji W, Boccardi E, et al. . Aneurysm Study of Pipeline in an Observational Registry (ASPIRe). Interv Neurol 2016;5:89–99. 10.1159/000446503 - DOI - PMC - PubMed
    1. Becske T, Kallmes DF, Saatci I, et al. . Pipeline for uncoilable or failed aneurysms: results from a multicenter clinical trial. Radiology 2013;267:858–68. 10.1148/radiol.13120099 - DOI - PubMed
    1. Aguilar-Salinas P, Brasiliense LB, Gonsales D, et al. . Evaluation of pipeline flex delivery system for the treatment of unruptured aneurysms. Expert Rev Med Devices 2016;13:885–97. 10.1080/17434440.2016.1231573 - DOI - PubMed
    1. Girdhar G, Li J, Kostousov L, et al. . In-vitro thrombogenicity assessment of flow diversion and aneurysm bridging devices. J Thromb Thrombolysis 2015;40:437–43. 10.1007/s11239-015-1228-0 - DOI - PubMed

Publication types

MeSH terms

Associated data