Short-Term Circulatory and Right Ventricle Support in Cardiogenic Shock: Extracorporeal Membrane Oxygenation, Tandem Heart, CentriMag, and Impella
- PMID: 30266366
- DOI: 10.1016/j.hfc.2018.06.014
Short-Term Circulatory and Right Ventricle Support in Cardiogenic Shock: Extracorporeal Membrane Oxygenation, Tandem Heart, CentriMag, and Impella
Abstract
Severe right ventricular (RV) failure is a significant cause of morbidity and mortality, with an in-hospital mortality rate up to 70% to 75%. Medical management is employed and is successful for most of these patients. However, a small percentage of patients will continue to have persistent RV failure, for which mechanical support is used for management.
Keywords: Cardiac surgery; Heart failure; Mechanical circulatory support; Right ventricular failure.
Copyright © 2018 Elsevier Inc. All rights reserved.
Similar articles
-
Percutaneous Mechanical Circulatory Support Devices in Cardiogenic Shock.Circ Cardiovasc Interv. 2017 May;10(5):e004337. doi: 10.1161/CIRCINTERVENTIONS.116.004337. Circ Cardiovasc Interv. 2017. PMID: 28500136 Free PMC article. Review.
-
Minimally invasive CentriMag ventricular assist device support integrated with extracorporeal membrane oxygenation in cardiogenic shock patients: a comparison with conventional CentriMag biventricular support configuration.Eur J Cardiothorac Surg. 2017 Dec 1;52(6):1055-1061. doi: 10.1093/ejcts/ezx189. Eur J Cardiothorac Surg. 2017. PMID: 28651347
-
Successful Treatment of Refractory Status Asthmaticus Accompanied by Right Ventricular Dysfunction Using a Protek Duo Tandem Heart Device.J Cardiothorac Vasc Anesth. 2019 Nov;33(11):3085-3089. doi: 10.1053/j.jvca.2019.03.031. Epub 2019 Mar 18. J Cardiothorac Vasc Anesth. 2019. PMID: 31076305 No abstract available.
-
Acute Biventricular Mechanical Circulatory Support for Cardiogenic Shock.J Am Heart Assoc. 2017 Oct 20;6(10):e006670. doi: 10.1161/JAHA.117.006670. J Am Heart Assoc. 2017. PMID: 29054842 Free PMC article.
-
Percutaneous support of the failing left and right ventricle-recommendations for the use of mechanical device therapy.Heart Fail Rev. 2018 Nov;23(6):831-839. doi: 10.1007/s10741-018-9730-z. Heart Fail Rev. 2018. PMID: 30058015 Review.
Cited by
-
Commentary: Aortic valve disease: Getting in the way of mechanical circulatory support.JTCVS Tech. 2020 Dec 5;5:80-81. doi: 10.1016/j.xjtc.2020.11.031. eCollection 2021 Feb. JTCVS Tech. 2020. PMID: 34318114 Free PMC article. No abstract available.
-
Impact of inhaled nitric oxide therapy in patients with cardiogenic shock treated with veno-arterial extracorporeal membrane oxygenation combined with Impella: a retrospective cohort study.J Intensive Care. 2024 Nov 18;12(1):49. doi: 10.1186/s40560-024-00761-z. J Intensive Care. 2024. PMID: 39558216 Free PMC article.
-
The Management of Cardiogenic Shock From Diagnosis to Devices: A Narrative Review.CHEST Crit Care. 2024 Jun;2(2):100071. doi: 10.1016/j.chstcc.2024.100071. Epub 2024 Apr 16. CHEST Crit Care. 2024. PMID: 38993934 Free PMC article.
-
Mechanical Circulatory Support for Right Ventricular Failure.Card Fail Rev. 2022 Apr 21;8:e14. doi: 10.15420/cfr.2021.11. eCollection 2022 Jan. Card Fail Rev. 2022. PMID: 35516793 Free PMC article. Review.
-
Extracorporeal life support to ventricular assist device: potential benefits of sternal-sparing approach.J Thorac Dis. 2019 Nov;11(11):4790-4797. doi: 10.21037/jtd.2019.10.21. J Thorac Dis. 2019. PMID: 31903269 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical