Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2019 Apr 1:130:344-351.
doi: 10.1016/j.bios.2018.09.046. Epub 2018 Sep 13.

3D cell-based biosensor for cell viability and drug assessment by 3D electric cell/matrigel-substrate impedance sensing

Affiliations

3D cell-based biosensor for cell viability and drug assessment by 3D electric cell/matrigel-substrate impedance sensing

Yuxiang Pan et al. Biosens Bioelectron. .

Abstract

Preclinical efficacy and toxicity assessment of drug candidates plays a significant role in drug discovery and development. Traditional planar cell culture is a common way to perform the preclinical drug test, but it is difficult to correctly predict the drug efficacy and toxicity due to the simple two-dimensional (2D) extracellular microenvironment. Compared to the planar cell culture, three-dimensional (3D) cell culture system can better mimic the complex extracellular microenvironment where cells reside in the 3D tissues/organs in vivo. However, the conventional imaging techniques are difficult to achieve the dynamic and label-free monitoring of cellular behavior in thick sample by 3D cell culture. Here, 3D electric cell/matrigel-substrate impedance sensing (3D-ECMIS) is developed for real-time and non-invasive monitoring of 3D cell viability and drug susceptibility. In this study, human hepatoma cells (HepG2) are encapsulated in the matrigel scaffold and cultured in a 3D ECMIS chip which involves a pair of vertical golden electrodes on the opposite sidewalls of the culture chamber for the in-situ impedance measurement. Moreover, a portable multichannel system is developed to monitor the 3D cell/matrigel construct. The number of 3D-cultured cells was inversely proportional to the impedance magnitude of the entire cell/matrigel construct. Furthermore, anti-cancer drug screening will be conducted on the 3D-cultured cells when the cell proliferation reaches to a plateau phase. To validate the performance of 3D-ECMIS for the cell viability and drug susceptibility, the cell live/dead staining are utilized to confirm the results of drug susceptibility by this 3D-cell-based biosensor system. It is demonstrated that the 3D cell-based biosensor and 3D-ECMIS system will be a promising platform to improve the accuracy of cell-based anti-cancer drug screening in vitro.

Keywords: 3D cell viability; 3D cell-based biosensors; 3D electric cell/matrigel-substrate impedance sensing; Anti-cancer drug screening in vitro.

PubMed Disclaimer