Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2019 Jul;43(7):1709-1714.
doi: 10.1007/s00264-018-4177-3. Epub 2018 Sep 29.

Outcomes of distal femur fractures treated with the Synthes 4.5 mm VA-LCP Curved Condylar Plate

Affiliations

Outcomes of distal femur fractures treated with the Synthes 4.5 mm VA-LCP Curved Condylar Plate

Khang H Dang et al. Int Orthop. 2019 Jul.

Abstract

Purpose: Given the recent controversy in the literature and the alarming reports of early mechanical failure associated with the use of the Synthes 4.5 mm VA-LCP Curved Condylar Plate in acute distal femur fractures, the goal of our study was to examine the outcomes and mechanical failure rates of this implant in a larger patient population.

Methods: Patients 18 years of age and older who underwent plate fixation of their acute distal femoral fracture using the Synthes 4.5 mm VA-LCP Curved Condylar Plate were included in this retrospective study. The study data was collected through a retrospective chart review and review of the existing radiographic studies. Primary outcome measure was mechanical hardware failure while secondary outcome measures included nonunion, malunion, and medical and surgical complications.

Results: A total of 74 patients (77 fractures) were included in this study. The fractures were classified according to the OTA/AO classification as 33-A2 (n = 6), 33-A3 (n = 19), 33-C1 (n = 5), 33-C2 (n = 25), and 33-C3 (n = 22). Thirty-two out of 77 fractures presented as open fractures (41.6%). A mechanical failure was observed in 7 patients (9.1%). Twenty additional patients needed a re-operation of the surgical site including two nonunion repairs, one malunion repair, 15 staged treatments of traumatic segmental bone defects, and two soft tissue debridements.

Conclusions: In our experience, the Synthes 4.5 mm VA-LCP Curved Condylar Plate is a safe and effective implant with a relatively low mechanical failure rate.

Keywords: Complication; Distal femur; Fracture; Locked plate.

PubMed Disclaimer

References

    1. Open Orthop J. 2014 Feb 21;8:34-40 - PubMed
    1. J Orthop Trauma. 2004 Sep;18(8):509-20 - PubMed
    1. J Orthop Trauma. 2016 Jan;30(1):e7-e11 - PubMed
    1. Clin Orthop Relat Res. 2011 Jun;469(6):1757-65 - PubMed
    1. Int Orthop. 2018 Nov;42(11):2675-2683 - PubMed

LinkOut - more resources