. 2018 Oct;11(5):742-746.
doi: 10.1093/ckj/sfy004. Epub 2018 Feb 26.

Evaluation of the efficacy of a medium cut-off dialyser and comparison with other high-flux dialysers in conventional haemodialysis and online haemodiafiltration

Affiliations

Evaluation of the efficacy of a medium cut-off dialyser and comparison with other high-flux dialysers in conventional haemodialysis and online haemodiafiltration

Ana García-Prieto et al. Clin Kidney J. 2018 Oct.

Abstract

Background: Online haemodiafiltration (OL-HDF) has been shown to reduce all-cause mortality versus conventional haemodialysis (HD); however, it is not always available. In these situations, a novel class of membranes with a higher pore size, medium cut-off (MCO) dialysers, could be promising. The aim of this study is to evaluate the efficacy of an MCO dialyser in the removal of small and medium-size molecules and compare it with standard high-flux (HF) dialysers in HD and OL-HDF.

Methods: In this crossover study, 18 prevalent HD patients were studied in three single mid-week dialysis treatments during three consecutive weeks as follows: first week with OL-HDF with a standard HF dialyser, second week with conventional HD with a standard HF dialyser and third week with conventional HD with an MCO dialyser. Reduction ratios (RRs) of different-sized molecules and albumin losses were collected for the different dialysers.

Results: MCO HD provided a greater reduction of middle and larger middle molecules compared with standard HF HD [rate reduction (RR) β2-microglobulin 74.7% versus 69.7%, P=0.01; RR myoglobin 62.5% versus 34.3%, P=0.001; RR prolactin 60% versus 32.8%, P=0.001; RR α1-glycoprotein 2.8% versus -0.1%, P=0.01]. We found no difference in the clearance of small and larger middle molecules comparing MCO HD with OL-HDF. Albumin losses were 0.03 g/session with MCO HD and 3.1 g/session with OL-HDF (P=0.001).

Conclusion: MCO HD is superior to standard HF HD in the removal of middle and larger middle molecules and it is not inferior to OL-HDF in the clearance of small and larger middle molecules. Thus it could be an alternative in patients in which it is not possible to perform OL-HDF.

Keywords: chronic haemodialysis; dialysis; dialysis adequacy; haemodialysis; uraemic toxins.

PubMed Disclaimer

References

    1. Registro Español de Enfermos Renales. Informe 2013 y evolución 2007–2013. Nefrología 2016; 36: 97–120
    1. Lisowska-Myjak B. Uremic toxins and their effects on multiple organ systems. Nephron Clin Pract 2014; 128: 303–311 - PubMed
    1. Vanholder RC, Eloot S, Glorieux GL.. Future avenues to decrease uremic toxin concentration. Am J Kidney Dis 2016; 67: 664–676 - PubMed
    1. Glorieux G, Vanholder R.. New uraemic toxins—which solutes should be removed? Contrib Nephrol 2011; 168: 117–128 - PubMed
    1. Eknoyan G, Beck GJ, Cheung AK. et al. Effect of dialysis dose and membrane flux in maintenance hemodialysis. N Engl J Med 2002; 347: 2010–2019 - PubMed