Virtual touch IQ elastography in evaluation of Achilles tendon in patients with chronic renal failure
- PMID: 30291574
- DOI: 10.1007/s10396-018-0907-9
Virtual touch IQ elastography in evaluation of Achilles tendon in patients with chronic renal failure
Abstract
Purpose: To evaluate the sonoelastographic changes in the Achilles tendon in patients with chronic renal failure (CRF) using virtual touch imaging quantification (VTIQ) elastography.
Methods: Twenty-six patients undergoing three hemodialysis sessions per week and 26 subjects admitted to our institution between January 2016 and April 2016 were included in this prospective study. The characteristics and body mass index of the patients were noted. Ultrasonography was performed parallel to the long axis of the bilateral Achilles tendons during relaxation of the legs using the Siemens Acuson S3000™ ultrasound device (Siemens HealthCare, Erlangen, Germany). Tendon thickness was reviewed, and tissue stiffness was quantitatively assessed using VTIQ elastography. Independent samples t test and Mann-Whitney U test were used for statistical analyses.
Results: The median values of shear wave velocities of the Achilles tendon in patients with CRF were 7.19 m/s (4.23-9.77 m/s) on the right and 6.98 m/s (4.00-9.82 m/s) on the left, while they were 5.11 m/s (4.09-8.82 m/s) on the right and 5.36 m/s (4.05-8.80 m/s) on the left in controls. The stiffness of the Achilles tendons in patients with CRF was found to be higher than that in controls (right: P < 0.001, left: P = 0.004). There was no statistically significant difference in tendon thickness between the CRF and control groups (P > 0.05).
Conclusion: The thickness and stiffness of tendon can be effectively evaluated with sonoelastography. The thickness of the Achilles tendon did not significantly differ between the patients with CRF and healthy subjects. However, the stiffness of the Achilles tendon measured with VTIQ elastography was demonstrated to be increased in the patients with CRF.
Keywords: Achilles tendon; Elastography; Hemodialysis; VTIQ.
Similar articles
-
Acoustic Radiation Force Impulse Elastography Findings of Achilles Tendons in Patients on Chronic Hemodialysis and in Renal Transplant Patients.Exp Clin Transplant. 2021 Jun;19(6):534-538. doi: 10.6002/ect.2018.0015. Epub 2018 Nov 6. Exp Clin Transplant. 2021. PMID: 30398098
-
Elasticity standard values of the Achilles tendon assessed with acoustic radiation force impulse elastography on healthy volunteers: a cross section study.BMC Musculoskelet Disord. 2018 May 9;19(1):139. doi: 10.1186/s12891-018-2056-0. BMC Musculoskelet Disord. 2018. PMID: 29743056 Free PMC article.
-
Shear wave elastography of the testes in a healthy study collective - Differences in standard values between ARFI and VTIQ techniques.Clin Hemorheol Microcirc. 2016;64(4):721-728. doi: 10.3233/CH-168052. Clin Hemorheol Microcirc. 2016. PMID: 27935546
-
Is sonoelastography of value in assessing tendons?Semin Musculoskelet Radiol. 2010 Sep;14(3):323-33. doi: 10.1055/s-0030-1254521. Epub 2010 Jun 10. Semin Musculoskelet Radiol. 2010. PMID: 20539957 Review.
-
The Use of Shear-Wave Ultrasound Elastography in the Diagnosis and Monitoring of Musculoskeletal Injuries.Crit Rev Biomed Eng. 2024;52(2):15-26. doi: 10.1615/CritRevBiomedEng.2023049807. Crit Rev Biomed Eng. 2024. PMID: 38305275 Review.
Cited by
-
Characterizing Musculoskeletal Tissue Mechanics Based on Shear Wave Propagation: A Systematic Review of Current Methods and Reported Measurements.Ann Biomed Eng. 2022 Jul;50(7):751-768. doi: 10.1007/s10439-022-02935-y. Epub 2022 Mar 31. Ann Biomed Eng. 2022. PMID: 35359250 Free PMC article.
References
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical
Miscellaneous