Effects of freeze-thaw on the biomechanical and structural properties of the rat Achilles tendon
- PMID: 30293824
- DOI: 10.1016/j.jbiomech.2018.09.012
Effects of freeze-thaw on the biomechanical and structural properties of the rat Achilles tendon
Abstract
Rodent models are commonly used to investigate tendon healing, with the biomechanical and structural properties of the healed tendons being important outcome measures. Tendon storage for later testing becomes necessary when performing large experiments with multiple time-points. However, it is unclear whether freezing rodent tendons affects their material properties. Thus the aim of this study was to determine whether freezing rat Achilles tendons affects their biomechanical or structural properties. Tendons were frozen at either -20 °C or -80 °C directly after harvesting, or tested when freshly harvested. Groups of tendons were subjected to several freeze-thaw cycles (1, 2, and 5) within 3 months, or frozen for 9 months, after which the tendons were subjected to biomechanical testing. Additionally, fresh and thawed tendons were compared morphologically, histologically and by transmission electron microscopy. No major differences in biomechanical properties were found between fresh tendons and those frozen once or twice at -20 °C or -80 °C. However, deterioration of tendon properties was found for 5-cycle groups and both long-term freezing groups; after 9 months of freezing at -80 °C the tear resistance of the tendon was reduced from 125.4 ± 16.4N to 74.3 ± 18.4N (p = 0.0132). Moreover, tendons stored under these conditions showed major disruption of collagen fibrils when examined by transmission electron microscopy. When examined histologically, fresh samples exhibited the best cellularity and proteoglycan content of the enthesis. These properties were preserved better after freezing at -80 °C than after freezing at -20 °C, which resulted in markedly smaller chondrocytes and less proteoglycan content. Overall, the best preservation of histological integrity was seen with tendons frozen once at -80 °C. In conclusion, rat Achilles tendons can be frozen once or twice for short periods of time (up to 3 months) at -20 °C or -80 °C for later testing. However, freezing for 9 months at either -20 °C or -80 °C leads to deterioration of certain parameters.
Keywords: Biomechanical testing; Freeze-thaw; Histology; Rat Achilles tendon; Ultra-structure.
Copyright © 2018 Elsevier Ltd. All rights reserved.
Similar articles
-
The influence of freezing on the tensile strength of tendon grafts : a biomechanical study.Acta Orthop Belg. 2013 Aug;79(4):435-43. Acta Orthop Belg. 2013. PMID: 24205775
-
Cryopreservation of tendon tissue using dimethyl sulfoxide combines conserved cell vitality with maintained biomechanical features.PLoS One. 2019 Apr 19;14(4):e0215595. doi: 10.1371/journal.pone.0215595. eCollection 2019. PLoS One. 2019. PMID: 31002728 Free PMC article.
-
Repeated freeze-thaw cycles reduce the survival rate of osteocytes in bone-tendon constructs without affecting the mechanical properties of tendons.Cell Tissue Bank. 2012 Mar;13(1):71-80. doi: 10.1007/s10561-010-9234-0. Epub 2010 Nov 30. Cell Tissue Bank. 2012. PMID: 21116722 Free PMC article.
-
The structure and function of normally mineralizing avian tendons.Comp Biochem Physiol A Mol Integr Physiol. 2002 Dec;133(4):1135-57. doi: 10.1016/s1095-6433(02)00248-9. Comp Biochem Physiol A Mol Integr Physiol. 2002. PMID: 12485697 Review.
-
Exploring the role of hypercholesterolemia in tendon health and repair.Muscles Ligaments Tendons J. 2014 Nov 17;4(3):275-9. eCollection 2014 Jul. Muscles Ligaments Tendons J. 2014. PMID: 25489542 Free PMC article. Review.
Cited by
-
A pilot study on lengthening potentials and biomechanical effects of double and triple hemisection on tendon with slide lengthening.Sci Rep. 2023 Mar 9;13(1):3922. doi: 10.1038/s41598-023-30791-w. Sci Rep. 2023. PMID: 36894616 Free PMC article.
-
Enthesis Healing Is Dependent on Scaffold Interphase Morphology-Results from a Rodent Patellar Model.Cells. 2022 May 26;11(11):1752. doi: 10.3390/cells11111752. Cells. 2022. PMID: 35681447 Free PMC article.
-
Elevated fluid and glycosaminoglycan content in the Achilles tendon contribute to higher intratendinous pressures: Implications for Achilles tendinopathy.J Sport Health Sci. 2024 Nov;13(6):863-871. doi: 10.1016/j.jshs.2024.04.004. Epub 2024 Apr 4. J Sport Health Sci. 2024. PMID: 38582138 Free PMC article.
-
Early Joint Use Following Elbow Dislocation Limits Range-of-Motion Loss and Tissue Pathology in Posttraumatic Joint Contracture.J Bone Joint Surg Am. 2023 Feb 1;105(3):223-230. doi: 10.2106/JBJS.22.00064. Epub 2022 Dec 2. J Bone Joint Surg Am. 2023. PMID: 36723466 Free PMC article.
-
Comparison of cortical versus cancellous bone fixation in tendon-to-bone healing with a rat trans-calcaneal suture model for Achilles tendon sleeve avulsion.J Orthop Surg Res. 2023 Jan 5;18(1):15. doi: 10.1186/s13018-022-03469-8. J Orthop Surg Res. 2023. PMID: 36604674 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources