Fluid Challenge During Anesthesia: A Systematic Review and Meta-analysis
- PMID: 30300177
- DOI: 10.1213/ANE.0000000000003834
Fluid Challenge During Anesthesia: A Systematic Review and Meta-analysis
Abstract
Background: Assessing the volemic status of patients undergoing surgery is part of the routine management for the anesthesiologist. This assessment is commonly performed by means of dynamic indexes based on the cardiopulmonary interaction during mechanical ventilation (if available) or by administering a fluid challenge (FC). The FC is used during surgery to optimize predefined hemodynamic targets, the so-called Goal-Directed Therapy (GDT), or to correct hemodynamic instability (non-GDT).
Methods: In this systematic review, we considered the FC components in studies adopting either GDT or non-GDT, to assess whether differences exist between the 2 approaches. In addition, we performed a meta-analysis to ascertain the effectiveness of dynamic indexes pulse pressure variation (PPV) and stroke volume (SV) variation (SVV), in predicting fluid responsiveness.
Results: Thirty-five non-GDT and 33 GDT studies met inclusion criteria, including 5017 patients. In the vast majority of non-GDT and GDT studies, the FC consisted in the administration of colloids (85.7% and 90.9%, respectively). In 29 non-GDT studies, the colloid infused was the 6% hydroxyethyl starch (6% HES; 96.6% of this subgroup). In 20 GDT studies, the colloid infused was the 6% HES (66.7% of this subgroup), while in 5 studies was a gelatin (16.7% of this subgroup), in 3 studies an unspecified colloid (10.0% of this subgroup), and in 1 study albumin (3.3%) or, in another study, both HES 6% and gelatin (3.3%). In non-GDT studies, the median volume infused was 500 mL; the time of infusion and hemodynamic target to assess fluid responsiveness lacked standardization. In GDT studies, FC usually consisted in the administration of 250 mL of colloids (48.8%) in 10 minutes (45.4%) targeting an SV increase >10% (57.5%). Only in 60.6% of GDT studies, a safety limit was adopted. PPV pooled area under the curve (95% confidence interval [CI]) was 0.86 (0.80-0.92). The mean (standard deviation) PPV threshold predicting fluid responsiveness was 10.5% (3.2) (range, 8%-15%), while the pooled (95% CI) sensitivity and specificity were 0.80 (0.74-0.85) and 0.83 (0.73-0.91), respectively. SVV pooled area under the curve (95% CI) was 0.87 (0.81-0.93). The mean (standard deviation) SVV threshold predicting fluid responsiveness was 11.3% (3.1) (range, 7.5%-15.5%), while the pooled (95% CI) sensitivity and specificity were 0.82 (0.75-0.89) and 0.77 (0.71-0.82), respectively.
Conclusions: The key components of FC including type of fluid (colloids, often 6% HES), volume (500 and 250 mL in non-GDT studies and GDT studies, respectively), and time of infusion (10 minutes) are quite standardized in operating room. However, pooled sensitivity and specificity of both PPV and SVV are limited.
Similar articles
-
Non-invasive measurements of pulse pressure variation and stroke volume variation in anesthetized patients using the Nexfin blood pressure monitor.J Clin Monit Comput. 2016 Oct;30(5):587-94. doi: 10.1007/s10877-015-9759-7. Epub 2015 Aug 29. J Clin Monit Comput. 2016. PMID: 26318314 Free PMC article.
-
Reliability of pulse pressure and stroke volume variation in assessing fluid responsiveness in the operating room: a metanalysis and a metaregression.Crit Care. 2023 Nov 8;27(1):431. doi: 10.1186/s13054-023-04706-0. Crit Care. 2023. PMID: 37940953 Free PMC article.
-
Assessment of Fluid Responsiveness in Prone Neurosurgical Patients Undergoing Protective Ventilation: Role of Dynamic Indices, Tidal Volume Challenge, and End-Expiratory Occlusion Test.Anesth Analg. 2020 Mar;130(3):752-761. doi: 10.1213/ANE.0000000000004494. Anesth Analg. 2020. PMID: 31651455
-
[Stroke volume and pulse pressure variation are good predictors of fluid responsiveness in sepsis patients].Acta Med Croatica. 2013 Dec;67(5):407-14. Acta Med Croatica. 2013. PMID: 24979881 Croatian.
-
A systematic review of pulse pressure variation and stroke volume variation to predict fluid responsiveness during cardiac and thoracic surgery.J Clin Monit Comput. 2017 Aug;31(4):677-684. doi: 10.1007/s10877-016-9898-5. Epub 2016 Jun 15. J Clin Monit Comput. 2017. PMID: 27306799
Cited by
-
Impact of the fluid challenge infusion rate on cardiac stroke volume during major spinal neurosurgery: a prospective single center randomized interventional trial.BMC Anesthesiol. 2022 Dec 23;22(1):400. doi: 10.1186/s12871-022-01945-6. BMC Anesthesiol. 2022. PMID: 36564704 Free PMC article. Clinical Trial.
-
Prediction of Fluid Responsiveness Using Combined End-Expiratory and End-Inspiratory Occlusion Tests in Cardiac Surgical Patients.J Clin Med. 2023 Mar 29;12(7):2569. doi: 10.3390/jcm12072569. J Clin Med. 2023. PMID: 37048651 Free PMC article.
-
Fluid challenge in critically ill patients receiving haemodynamic monitoring: a systematic review and comparison of two decades.Crit Care. 2022 Jun 21;26(1):186. doi: 10.1186/s13054-022-04056-3. Crit Care. 2022. PMID: 35729632 Free PMC article.
-
Functional hemodynamic tests: a systematic review and a metanalysis on the reliability of the end-expiratory occlusion test and of the mini-fluid challenge in predicting fluid responsiveness.Crit Care. 2019 Jul 29;23(1):264. doi: 10.1186/s13054-019-2545-z. Crit Care. 2019. PMID: 31358025 Free PMC article.
-
Fluid boluses and infusions in the early phase of resuscitation from septic shock and sepsis-induced hypotension: a retrospective report and outcome analysis from a tertiary hospital.Ann Intensive Care. 2024 Aug 15;14(1):123. doi: 10.1186/s13613-024-01347-6. Ann Intensive Care. 2024. PMID: 39147957 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical
Miscellaneous