Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2019 Apr;52(4):461-474.
doi: 10.1111/iej.13027. Epub 2018 Oct 29.

Chemical biofilm removal capacity of endodontic irrigants as a function of biofilm structure: optical coherence tomography, confocal microscopy and viscoelasticity determination as integrated assessment tools

Affiliations

Chemical biofilm removal capacity of endodontic irrigants as a function of biofilm structure: optical coherence tomography, confocal microscopy and viscoelasticity determination as integrated assessment tools

F H Busanello et al. Int Endod J. 2019 Apr.

Abstract

Aim: To investigate the influence of biofilm structure on the biofilm removal capacity of endodontic irrigants and to study changes in the architecture of the remaining biofilms.

Methodology: Streptococcus oralis J22 and Actinomyces naeslundii T14V-J1 were cocultured under different growth conditions on saliva-coated hydroxyapatite discs. A constant depth film fermenter (CDFF) was used to grow steady-state 4-day biofilms. Biofilms were grown under static conditions for 4 and 10 days within a confined space. Twenty microlitres of 2% NaOCl, 2% Chlorhexidine (CHX), 17% Ethylene-diamine-tetra-acetic acid (EDTA) and buffer were applied statically on the biofilms for 60 s. Biofilm removal was evaluated with optical coherence tomography (OCT). Post-treated biofilms were assessed via low load compression testing (LLCT) and Confocal laser scanning microscopy (CLSM). Optical coherence tomography data were analysed through a two-way analysis of variance (ANOVA). Low load compression testing and CLSM data were analysed through one-way ANOVA and Dunnett's post hoc test. The level of significance was set at a < 0.05.

Results: The initial biofilm structure affected the biofilm removal capacity of the irrigants. NaOCl demonstrated the greatest chemical efficacy against the biofilms and was significantly more effective on the static than the CDFF biofilms (P < 0.001). CHX was ineffective and caused a rearrangement of the biofilm structure. Ethylene-diamine-tetra-acetic acid exhibited a distinct removal effect only on the CDFF biofilms. Biofilm age influenced the structure of the remaining biofilms. The 4-day grown remaining biofilms had a significantly different viscoelastic pattern compared to the respective 10-day grown biofilms (P ≤ 0.01), especially in the NaOCl-treated group. Confocal laser scanning microscopy analysis confirmed the CHX-induced biofilm structural rearrangement.

Conclusions: Biofilm structure is an influential factor on the chemical efficacy of endodontic irrigants. Optical coherence tomography allows biofilm removal characteristics to be studied. NaOCl should remain the primary irrigant. Ethylene-diamine-tetra-acetic acid was effective against cell-rich/EPS-poor biofilms. Chlorhexidine did not remove biofilm, but rather rearranged its structure.

Keywords: biofilm; irrigants; optical coherence tomography; removal; structure; viscoelasticity.

PubMed Disclaimer

LinkOut - more resources