Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2018 Oct:29 Suppl 18:184-195.
doi: 10.1111/clr.13300.

Is the use of digital technologies for the fabrication of implant-supported reconstructions more efficient and/or more effective than conventional techniques: A systematic review

Affiliations
Free article

Is the use of digital technologies for the fabrication of implant-supported reconstructions more efficient and/or more effective than conventional techniques: A systematic review

Sven Mühlemann et al. Clin Oral Implants Res. 2018 Oct.
Free article

Abstract

Objective: To identify clinical studies evaluating efficiency and/or effectiveness of digital technologies as compared to conventional manufacturing procedures for the fabrication of implant-supported reconstructions.

Materials and methods: A systematic search from 1990 through July 2017 was performed using the online databases Medline, Embase, and Cochrane-Central-Register-of-Controlled-Trials. Literature on efficiency and/or effectiveness during the impression session, the manufacturing process, and the delivery session were included.

Results: In total, 12 clinical studies were included. No meta-analysis was performed due to a large heterogeneity of the study protocols. Nine publications reported on posterior single implant crowns (SIC) and three on full-arch reconstructions. Mean impression time with intraoral scanners ranged between 6.7 and 19.8 min, whereas the range for conventional impressions was 8.8 and 18.4 min. In a fully digital workflow (FD-WF) for posterior SIC, mean fabrication time ranged between 46.8 and 54.5 min (prefabricated abutment) and 68.0 min (customized abutment). In a hybrid workflow (H-WF) including a digitally customized abutment and a manual veneering, mean fabrication time ranged between 132.5 and 158.1 min. For a conventional porcelain-fused-to-metal-crown, a mean time of 189.8 min was reported. The mean time for the delivery of posterior SIC ranged between 7.3 and 7.4 min (FD-WF), 10.5 and 12.5 min (H-WF), and 15.3 min (conventional workflow, C-WF). The FD-WF for posterior SIC was more effective than the H-/C-WF.

Conclusions: The implementation of the studied digital technologies increased time efficiency for the laboratory fabrication of implant-supported reconstructions. For posterior SIC, the model-free fabrication, the use of prefabricated abutments, and the monolithic design was most time efficient and most effective.

PubMed Disclaimer

Publication types

MeSH terms