Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2018 Dec;58(12):2886-2893.
doi: 10.1111/trf.14919. Epub 2018 Oct 16.

Human immunodeficiency virus 1 dual-target nucleic acid technology improves blood safety: 5 years of experience of the German Red Cross blood donor service Baden-Württemberg-Hessen

Affiliations

Human immunodeficiency virus 1 dual-target nucleic acid technology improves blood safety: 5 years of experience of the German Red Cross blood donor service Baden-Württemberg-Hessen

Kai Hourfar et al. Transfusion. 2018 Dec.

Abstract

Background: RNA viruses are associated with a high frequency of mutations because of the missing proofreading function of polymerases, such as reverse transcriptase. Between 2007 and 2010, six blood donations with false-negative nucleic acid technology (NAT) results were reported in Germany. Therefore, NAT screening in two viral genome regions was introduced by our blood donation service in 2010 on a voluntary basis and became mandatory in Germany since the beginning of 2015.

Study design and methods: Blood donor screening was done using, in parallel, the German Red Cross (GRC) HIV-1 CE long terminate repeats (LTR) PCR kit and the GRC HIV-1 gag CE PCR kit. In total, 7 million blood donations were screened during the study period from 2010 to 2014 with the GRC dual-target human immunodeficiency virus 1 (HIV-1) NAT system. Additionally, three suspicious specimens were analyzed by four monotargeted NAT assays and by five dual-target NAT assays.

Results: Three of 7 million donations tested negative using the 5'LTR-polymerase chain reaction, but they were positive if amplification was performed in the gag region. HIV antibodies were detected in all three donations. Nucleic acid sequence analysis identified a deletion of 22 bases within the 5'LTR probe binding region. Three different ltr-based monotargeted assays missed two donations, except for a low-reactive result obtained by one of the assays. In total, the detection rates for HIV-1-positive donations were 37.5% (3/8) for monotargeted assays and 100% (10/10) for dual-target assays.

Conclusion: The current data demonstrate that dual-target NAT systems reduce the risk of false-negative HIV-1 NAT screening results.

PubMed Disclaimer

Publication types

Substances

LinkOut - more resources