Human perception of whole body roll-tilt orientation in a hypogravity analog: underestimation and adaptation
- PMID: 30332330
- DOI: 10.1152/jn.00140.2018
Human perception of whole body roll-tilt orientation in a hypogravity analog: underestimation and adaptation
Abstract
Overestimation of roll tilt in hypergravity ("G-excess" illusion) has been demonstrated, but corresponding sustained hypogravic conditions are impossible to create in ground laboratories. In this article we describe the first systematic experimental evidence that in a hypogravity analog, humans underestimate roll tilt. We studied perception of self-roll tilt in nine subjects, who were supine while spun on a centrifuge to create a hypogravity analog. By varying the centrifuge rotation rate, we modulated the centripetal acceleration (GC) at the subject's head location (0.5 or 1 GC) along the body axis. We measured orientation perception using a subjective visual vertical task in which subjects aligned an illuminated bar with their perceived centripetal acceleration direction during tilts (±11.5-28.5°). As hypothesized, based on the reduced utricular otolith shearing, subjects initially underestimated roll tilts in the 0.5 GC condition compared with the 1 GC condition (mean perceptual gain change = -0.27, P = 0.01). When visual feedback was given after each trial in 0.5 GC, subjects' perceptual gain increased in approximately exponential fashion over time (time constant = 16 tilts or 13 min), and after 45 min, the perceptual gain was not significantly different from the 1 GC baseline (mean gain difference between 1 GC initial and 0.5 GC final = 0.16, P = 0.3). Thus humans modified their interpretation of sensory cues to more correctly report orientation during this hypogravity analog. Quantifying the acute orientation perceptual learning in such an altered gravity environment may have implications for human space exploration on the moon or Mars. NEW & NOTEWORTHY Humans systematically overestimate roll tilt in hypergravity. However, human perception of orientation in hypogravity has not been quantified across a range of tilt angles. Using a centrifuge to create a hypogravity centripetal acceleration environment, we found initial underestimation of roll tilt. Providing static visual feedback, perceptual learning reduced underestimation during the hypogravity analog. These altered gravity orientation perceptual errors and adaptation may have implications for astronauts.
Keywords: G-shortage; learning; self-motion; utricular shear; vestibular.
Similar articles
-
Human manual control precision depends on vestibular sensory precision and gravitational magnitude.J Neurophysiol. 2018 Dec 1;120(6):3187-3197. doi: 10.1152/jn.00565.2018. Epub 2018 Oct 31. J Neurophysiol. 2018. PMID: 30379610 Free PMC article.
-
A Case Study of Human Roll Tilt Perception in Hypogravity.Aerosp Med Hum Perform. 2017 Jul 1;88(7):682-687. doi: 10.3357/AMHP.4823.2017. Aerosp Med Hum Perform. 2017. PMID: 28641686
-
Perception of tilt (somatogravic illusion) in response to sustained linear acceleration during space flight.Exp Brain Res. 2001 Jun;138(4):410-8. doi: 10.1007/s002210100706. Exp Brain Res. 2001. PMID: 11465738
-
Gravity or translation: central processing of vestibular signals to detect motion or tilt.J Vestib Res. 2003;13(4-6):245-53. J Vestib Res. 2003. PMID: 15096668 Review.
-
Interaction of vestibular, somatosensory and visual signals for postural control and motion perception under terrestrial and microgravity conditions--a conceptual model.Brain Res Brain Res Rev. 1998 Nov;28(1-2):118-35. doi: 10.1016/s0165-0173(98)00032-0. Brain Res Brain Res Rev. 1998. PMID: 9795180 Review.
Cited by
-
The Influence of Altered-Gravity on Bimanual Coordination: Retention and Transfer.Front Physiol. 2022 Jan 7;12:794705. doi: 10.3389/fphys.2021.794705. eCollection 2021. Front Physiol. 2022. PMID: 35069255 Free PMC article.
-
COMPASS: Computations for Orientation and Motion Perception in Altered Sensorimotor States.Front Neural Circuits. 2021 Oct 15;15:757817. doi: 10.3389/fncir.2021.757817. eCollection 2021. Front Neural Circuits. 2021. PMID: 34720889 Free PMC article.
-
Modeling orientation perception adaptation to altered gravity environments with memory of past sensorimotor states.Front Neural Circuits. 2023 Jul 20;17:1190582. doi: 10.3389/fncir.2023.1190582. eCollection 2023. Front Neural Circuits. 2023. PMID: 37547052 Free PMC article.
-
Effect of head roll-tilt on the subjective visual vertical in healthy participants: Towards better clinical measurement of gravity perception.Laryngoscope Investig Otolaryngol. 2020 Sep 24;5(5):941-949. doi: 10.1002/lio2.461. eCollection 2020 Oct. Laryngoscope Investig Otolaryngol. 2020. PMID: 33134543 Free PMC article.
-
Human manual control precision depends on vestibular sensory precision and gravitational magnitude.J Neurophysiol. 2018 Dec 1;120(6):3187-3197. doi: 10.1152/jn.00565.2018. Epub 2018 Oct 31. J Neurophysiol. 2018. PMID: 30379610 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical
Research Materials
Miscellaneous