Evaluation of Peak Wall Stress in an Ascending Thoracic Aortic Aneurysm Using FSI Simulations: Effects of Aortic Stiffness and Peripheral Resistance
- PMID: 30341731
- DOI: 10.1007/s13239-018-00385-z
Evaluation of Peak Wall Stress in an Ascending Thoracic Aortic Aneurysm Using FSI Simulations: Effects of Aortic Stiffness and Peripheral Resistance
Abstract
Purpose: It has been reported clinically that rupture or dissections in thoracic aortic aneurysms (TAA) often occur due to hypertension which may be modelled with sudden increase of peripheral resistance, inducing acute changes of blood volumes in the aorta. There is clinical evidence that more compliant aneurysms are less prone to rupture as they can sustain such changes of volume. The aim of the current paper is to verify this paradigm by evaluating computationally the role played by the variation of peripheral resistance and the impact of aortic stiffness onto peak wall stress in ascending TAA.
Methods: Fluid-structure interaction (FSI) analyses were performed using patient-specific geometries and boundary conditions derived from 4D MRI datasets acquired on a patient. Blood was assumed incompressible and was treated as a non-Newtonian fluid using the Carreau model while the wall mechanical properties were obtained from the bulge inflation tests carried out in vitro after surgical repair. The Navier-Stokes equations were solved in ANSYS Fluent. The Arbitrary Lagrangian-Eulerian formulation was used to account for the wall deformations. At the interface between the solid domain and the fluid domain, the fluid pressure was transferred to the wall and the displacement of the wall was transferred to the fluid. The two systems were connected by the System Coupling component which controls the solver execution of fluid and solid simulations in ANSYS. Fluid and solid domains were solved sequentially starting from the fluid simulations.
Results: Distributions of blood flow, wall shear stress and wall stress were evaluated in the ascending thoracic aorta using the FSI analyses. We always observed a significant flow eccentricity in the simulations, in very good agreement with velocity profiles measured using 4D MRI. The results also showed significant increase of peak wall stress due to the increase of peripheral resistance and aortic stiffness. In the worst case scenario, the largest peripheral resistance (1010 kg s m-4) and stiffness (10 MPa) resulted in a maximal principal stress equal to 702 kPa, whereas it was only 77 kPa in normal conditions.
Conclusions: This is the first time that the risk of rupture of an aTAA is quantified in case of the combined effects of hypertension and aortic stiffness increase. Our findings suggest that a stiffer TAA may have the most altered distribution of wall stress and an acute change of peripheral vascular resistance could significantly increase the risk of rupture for a stiffer aneurysm.
Keywords: 4D MRI; Aortic stiffness; Fluid–structure interactions; Peak wall stress; Risk of rupture; Thoracic aortic aneurysm.
Similar articles
-
A combined 4D flow MR imaging and fluid-structure interaction analysis of ascending thoracic aortic aneurysms.Biomech Model Mechanobiol. 2025 Jun;24(3):829-844. doi: 10.1007/s10237-025-01939-6. Epub 2025 Mar 11. Biomech Model Mechanobiol. 2025. PMID: 40067580 Free PMC article.
-
Wall stress analyses in patients with ≥5 cm versus <5 cm ascending thoracic aortic aneurysm.J Thorac Cardiovasc Surg. 2021 Nov;162(5):1452-1459. doi: 10.1016/j.jtcvs.2020.02.046. Epub 2020 Feb 19. J Thorac Cardiovasc Surg. 2021. PMID: 32178922 Free PMC article.
-
Validation of Numerical Simulations of Thoracic Aorta Hemodynamics: Comparison with In Vivo Measurements and Stochastic Sensitivity Analysis.Cardiovasc Eng Technol. 2018 Dec;9(4):688-706. doi: 10.1007/s13239-018-00387-x. Epub 2018 Oct 24. Cardiovasc Eng Technol. 2018. PMID: 30357714
-
Biomechanical Indices for Rupture Risk Estimation in Abdominal Aortic Aneurysms.J Endovasc Ther. 2017 Apr;24(2):254-261. doi: 10.1177/1526602816680088. Epub 2016 Nov 21. J Endovasc Ther. 2017. PMID: 27872318 Review.
-
Imaging-based biomechanical parameters for assessing risk of aortic dissection and rupture in thoracic aortic aneurysms.Eur J Cardiothorac Surg. 2025 Mar 28;67(4):ezaf128. doi: 10.1093/ejcts/ezaf128. Eur J Cardiothorac Surg. 2025. PMID: 40234250 Review.
Cited by
-
Computational Hemodynamic Modeling of Arterial Aneurysms: A Mini-Review.Front Physiol. 2020 May 12;11:454. doi: 10.3389/fphys.2020.00454. eCollection 2020. Front Physiol. 2020. PMID: 32477163 Free PMC article. Review.
-
A combined 4D flow MR imaging and fluid-structure interaction analysis of ascending thoracic aortic aneurysms.Biomech Model Mechanobiol. 2025 Jun;24(3):829-844. doi: 10.1007/s10237-025-01939-6. Epub 2025 Mar 11. Biomech Model Mechanobiol. 2025. PMID: 40067580 Free PMC article.
-
Deployment of a digital twin using the coupled momentum method for fluid-structure interaction: A case study for aortic aneurysm.Comput Biol Med. 2025 May;190:110084. doi: 10.1016/j.compbiomed.2025.110084. Epub 2025 Apr 3. Comput Biol Med. 2025. PMID: 40179810 Free PMC article.
-
4D flow imaging of the thoracic aorta: is there an added clinical value?Cardiovasc Diagn Ther. 2020 Aug;10(4):1068-1089. doi: 10.21037/cdt-20-452. Cardiovasc Diagn Ther. 2020. PMID: 32968661 Free PMC article. Review.
-
Fully-Coupled FSI Computational Analyses in the Ascending Thoracic Aorta Using Patient-Specific Conditions and Anisotropic Material Properties.Front Physiol. 2021 Oct 20;12:732561. doi: 10.3389/fphys.2021.732561. eCollection 2021. Front Physiol. 2021. PMID: 34744774 Free PMC article.