Intraocular intrusion in vitreous cavity of encirclage band following retinal detachment surgery
- PMID: 30355884
- PMCID: PMC6213685
- DOI: 10.4103/ijo.IJO_360_18
Intraocular intrusion in vitreous cavity of encirclage band following retinal detachment surgery
Conflict of interest statement
There are no conflicts of interest
Figures
References
-
- Wong IY, Wong D. Special adjuncts to treatment. In: Ryan SJ, editor. Retinal Reattachment: General Surgical Principles and Techniques. 5th ed. Elsevier Saunders: South-East Asia edition; 2013. p. 1737. Sec. 2, Ch. 104.
-
- Nguyen QD, Lashkari K, Hirose T, Pruett RC, McMeel JW, Schepens CL. Erosion and intrusion of silicone rubber scleral buckle. Presentation and management. Retina. 2001;21:214–20. - PubMed
-
- Yoshizumi MO, Friberg T. Erosion of implants in retinal detachment surgery. Ann Ophthalmol. 1983;15:430–4. - PubMed
-
- Lewis H, Aaberg TM, Packo KH, Richmond PP, Blumenkranz MS, Blankenship GW, et al. Intrusion of retinal tacks. Am J Ophthalmol. 1987;103:672–80. - PubMed
-
- Unlü N, Kocaoglan H, Acar MA, Aslan BS, Duman S. Intraocular intrusion of a scleral sponge implant. Ophthalmic Surg Lasers Imaging. 2003;34:223–5. - PubMed