Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2019 Jun;38(6):1569-1581.
doi: 10.1002/jum.14846. Epub 2018 Oct 29.

Development and Reliability of the Joint Tissue Activity and Damage Examination for Quantitation of Structural Abnormalities by Musculoskeletal Ultrasound in Hemophilic Joints

Affiliations
Free article

Development and Reliability of the Joint Tissue Activity and Damage Examination for Quantitation of Structural Abnormalities by Musculoskeletal Ultrasound in Hemophilic Joints

Lena M Volland et al. J Ultrasound Med. 2019 Jun.
Free article

Abstract

Objectives: Musculoskeletal ultrasound (US) is used increasingly to examine hemophilic arthropathy. However, quantitative algorithms to document findings are lacking. We developed and sought to validate a protocol quantifying hemophilic joint abnormalities.

Methods: Thirty-one patients with hemophilia were examined serially for 2 years with musculoskeletal US (≈600 joint examinations and ≈6000 images). Based on the spectrum of pathologies, a quantitative algorithm, named Joint Tissue Activity and Damage Examination (JADE), was developed for soft tissue and osteochondral measurements, including power Doppler, using nominal group techniques. To study intra- and inter-rater reliability, 8 musculoskeletal US-experienced hemophilia providers performed anatomic landmark recognition and tissue measurements on 86 images with arthropathic changes, with repetition 1 month later. Twenty-three musculoskeletal US-inexperienced providers performed similar assessments. Inter-operator reliability was established by 6 musculoskeletal US-experienced hemophilia providers, each acquiring images and JADE assessments of 3 hemophilic arthropathic joints. A radiologist and musculoskeletal sonographer functioned as adjudicators. The statistical analysis was performed with the intraclass correlation coefficient (ICC), Fleiss κ, and Cohen κ where appropriate.

Results: The musculoskeletal US-experienced providers showed excellent intra-and inter-rater reliability for tissue measurements (ICCs, 0.94-0.96). Agreement was good to excellent for landmark recognition (Fleiss κ, 0.87-0.94). Inter-operator reliability was excellent for measurements and landmark recognition (ICC, 0.90; Fleiss κ, 1.0). Agreement with adjudicators was mostly good to excellent. Musculoskeletal US-inexperienced providers showed excellent inter-rater reliability for measurements (ICC, 0.96) and moderate agreement for landmark recognition (Fleiss κ, 0.58).

Conclusions: The JADE protocol appears feasible for quantifying hemophilic intra-articular abnormalities. Musculoskeletal US-trained hemophilia providers showed high intra-rater, inter-rater, and inter-operator reliability, supporting JADE as a protocol for clinical management and research.

Keywords: arthropathy; hemophilia; inter-operator reliability; inter-rater reliability; musculoskeletal ultrasound; reliability.

PubMed Disclaimer