Cone-beam Computed Tomographic Analysis of Canal Transportation and Centering Ability of Single-file Systems
- PMID: 30390970
- DOI: 10.1016/j.joen.2018.09.011
Cone-beam Computed Tomographic Analysis of Canal Transportation and Centering Ability of Single-file Systems
Abstract
Introduction: The purpose of this study was to compare canal transportation and the centering ability of Reciproc (VDW, Munich, Germany), WaveOne (Dentsply Maillefer, Ballaigues, Switzerland), and EdgeFile (EdgeEndo, Albuquerque, NM) rotary systems using cone-beam computed tomographic imaging.
Methods: Ninety mesiobuccal mandibular first molar uncalcified canals with at least a 19-mm length, a canal curvature of 15°-30° (the Schneider method), and a mature apex were selected. Canals were randomly divided into 3 groups of 30 teeth, and canal preparation with the Reciproc, WaveOne, and EdgeFile systems was performed according to the manufacturers' instructions. Cone-beam computed tomographic images were taken before and after instrumentation in the same position. Apical transportation was calculated in the distances of 2, 3, and 4 mm from the apex. Kruskal-Wallis and Mann-Whitney U tests were used to statistically analyze the data.
Results: The mean canal transportation was significantly lower with EdgeFile (P < .001) followed by the WaveOne rotary system. Moreover, the centering ability of the EdgeFile system was higher than that of the WaveOne and Reciproc systems.
Conclusions: The EdgeFile rotary system showed the lowest transportation in both the mesiodistal and buccolingual directions and the highest centering ability. The Reciproc system showed the highest transportation and the lowest centering ability.
Keywords: EdgeFile; Reciproc; WaveOne; single file; transportation.
Copyright © 2018 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.
Similar articles
-
Comparative study of different novel nickel-titanium rotary systems for root canal preparation in severely curved root canals.J Endod. 2014 Jun;40(6):852-6. doi: 10.1016/j.joen.2013.10.010. Epub 2013 Nov 7. J Endod. 2014. PMID: 24862716
-
Micro-computed tomographic evaluation of canal transportation instrumented by different kinematics rotary nickel-titanium instruments.J Endod. 2014 Aug;40(8):1223-7. doi: 10.1016/j.joen.2014.01.039. Epub 2014 Mar 18. J Endod. 2014. PMID: 25069937
-
Effect of altering the reciprocation range on the fatigue life and the shaping ability of WaveOne nickel-titanium instruments.J Endod. 2013 May;39(5):685-8. doi: 10.1016/j.joen.2012.12.007. Epub 2013 Jan 26. J Endod. 2013. PMID: 23611391
-
Reciprocating vs Rotary Instrumentation in Pediatric Endodontics: Cone Beam Computed Tomographic Analysis of Deciduous Root Canals using Two Single-file Systems.Int J Clin Pediatr Dent. 2016 Jan-Mar;9(1):45-9. doi: 10.5005/jp-journals-10005-1332. Epub 2016 Apr 22. Int J Clin Pediatr Dent. 2016. PMID: 27274155 Free PMC article. Review.
-
A Critical Review of Methods for Quantitative Evaluation of Root Canal Transportation.J Endod. 2021 May;47(5):721-731. doi: 10.1016/j.joen.2021.02.002. Epub 2021 Feb 13. J Endod. 2021. PMID: 33587997 Review.
Cited by
-
Procedural errors detected by cone beam tomography in cases with indication for retreatment: in vivo cross-sectional study.Restor Dent Endod. 2024 Jun 24;49(3):e26. doi: 10.5395/rde.2024.49.e26. eCollection 2024 Aug. Restor Dent Endod. 2024. PMID: 39247645 Free PMC article.
-
Shaping ability of four single-file systems in the instrumentation of second mesiobuccal canals of three-dimensional printed maxillary first molars.Ann Transl Med. 2021 Sep;9(18):1425. doi: 10.21037/atm-21-3855. Ann Transl Med. 2021. PMID: 34733977 Free PMC article.
-
Evaluation of the Shaping Ability of Three Thermally Treated Nickel-Titanium Endodontic Instruments on Standardized 3D-printed Dental Replicas Using Cone-Beam Computed Tomography.Medicina (Kaunas). 2021 Aug 29;57(9):901. doi: 10.3390/medicina57090901. Medicina (Kaunas). 2021. PMID: 34577824 Free PMC article.
-
Evaluation of apical transportation and centering ability of three single-file systems in severely curved canals using micro-computed tomography.Dent Res J (Isfahan). 2024 Feb 22;21:12. eCollection 2024. Dent Res J (Isfahan). 2024. PMID: 38476716 Free PMC article.
-
Shaping Ability of F6 SkyTaper®, Hyflex® EDM One File, and One Curve®: A Micro-computed Tomographic Evaluation in Curved Root Canals.Eur Endod J. 2023 Mar;8(2):156-161. doi: 10.14744/eej.2022.55376. Eur Endod J. 2023. PMID: 37010202 Free PMC article.
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Miscellaneous