Virtual non-enhanced dual-energy CT reconstruction may replace true non-enhanced CT scans in the setting of suspected active hemorrhage
- PMID: 30392950
- DOI: 10.1016/j.ejrad.2018.10.026
Virtual non-enhanced dual-energy CT reconstruction may replace true non-enhanced CT scans in the setting of suspected active hemorrhage
Abstract
Objective: To assess virtual non-enhanced dual energy computed tomography (DECT) reconstruction as a potential alternative to true non-enhanced thoracic and abdominal CT scans in patients with suspected active hemorrhage.
Methods and materials: Ninety-seven consecutive patients with suspected active bleeding, who underwent routine triphasic CT with intravenous contrast, were included. All patients underwent single energy non-enhanced (TNE) and arterial phase CT as well as venous DECT. Using commercially available software, venous dual energy images were used to generate virtual non-enhanced images (VNE). TNE and VNE were evaluated regarding subjective image quality and diagnostic confidence on a 5-point-scale. The consistency of interpretation with respect to presence and type of hemorrhage between conventional triphasic CT including TNE and biphasic CT with simulated VNE was assessed by two blinded independent readers.
Results: Among the included subjects (mean age: 66.3 ± 14.5 years, 63.9% male), 37.1% were diagnosed with acute hemorrhage. VNE yielded significantly lower image quality but superior reduction of artefacts as compared to TNE (p ≤ 0.001). Diagnostic confidence was rated high for both TNE and VNE with a significant superiority of TNE (p = 0.003). Triphasic and biphasic CT datasets yielded perfect intrareader agreement regarding presence and type of hemorrhage. The interrater agreement was almost perfect (K = 0.955). Radiation dose was significantly reduced using biphasic dual energy CT with VNE (p ≤ 0.001).
Conclusion: Virtual non-enhanced images yield comparable diagnostic confidence and perfect agreement with true non-enhanced images for assessment of acute hemorrhage. This suggests that true non-enhanced images could be replaced by virtual non-enhanced images resulting in a significant reduction of radiation dose.
Keywords: Bleeding; Dual energy CT; Hemorrhage; True non-enhanced; Virtual unenhanced.
Copyright © 2018 Elsevier B.V. All rights reserved.
Similar articles
-
Virtual non-enhanced dual-energy computed tomography reconstruction: a candidate to replace true non-enhanced computed tomography scans in the setting of suspected liver alveolar echinococcosis.Diagn Interv Radiol. 2023 Nov 7;29(6):736-740. doi: 10.4274/dir.2023.221806. Epub 2023 Apr 12. Diagn Interv Radiol. 2023. PMID: 37042415 Free PMC article.
-
Dual-source dual-energy CT angiography with virtual non-enhanced images and iodine map for active gastrointestinal bleeding: image quality, radiation dose and diagnostic performance.Eur J Radiol. 2015 May;84(5):884-91. doi: 10.1016/j.ejrad.2015.01.013. Epub 2015 Jan 22. Eur J Radiol. 2015. PMID: 25650332
-
Virtual unenhanced CT images acquired from dual-energy CT urography: accuracy of attenuation values and variation with contrast material phase.Clin Radiol. 2013 Mar;68(3):264-71. doi: 10.1016/j.crad.2012.08.004. Epub 2012 Sep 10. Clin Radiol. 2013. PMID: 22974566
-
Dual-Energy CT of the Abdomen and Pelvis: Radiation Dose Considerations.J Am Coll Radiol. 2018 Aug;15(8):1128-1132. doi: 10.1016/j.jacr.2017.08.012. Epub 2017 Sep 22. J Am Coll Radiol. 2018. PMID: 28958720 Review.
-
The application of dual-energy computed tomography in the diagnosis of musculoskeletal disorders: a review of current concepts and applications.Radiol Med. 2019 Nov;124(11):1175-1183. doi: 10.1007/s11547-019-01015-x. Epub 2019 Mar 4. Radiol Med. 2019. PMID: 30828774 Review.
Cited by
-
Photon-counting CT urogram: optimal acquisition potential (kV) determination for virtual noncontrast creation.Abdom Radiol (NY). 2024 Mar;49(3):868-874. doi: 10.1007/s00261-023-04113-7. Epub 2023 Nov 25. Abdom Radiol (NY). 2024. PMID: 38006415
-
Advances in Novel Diagnostic Techniques for Alveolar Echinococcosis.Diagnostics (Basel). 2025 Feb 27;15(5):585. doi: 10.3390/diagnostics15050585. Diagnostics (Basel). 2025. PMID: 40075832 Free PMC article. Review.
-
Feasibility of replacing true non-contrast images with virtual non-contrast images in quantitative analysis of emphysema.Radiologie (Heidelb). 2025 May 8. doi: 10.1007/s00117-025-01448-8. Online ahead of print. Radiologie (Heidelb). 2025. PMID: 40341971 English.
-
Dual-Energy CT for Accurate Discrimination of Intraperitoneal Hematoma and Intestinal Structures.Diagnostics (Basel). 2022 Oct 20;12(10):2542. doi: 10.3390/diagnostics12102542. Diagnostics (Basel). 2022. PMID: 36292231 Free PMC article.
-
Differentiation of Hamartomas and Malignant Lung Tumors in Single-Phased Dual-Energy Computed Tomography.Tomography. 2024 Feb 11;10(2):255-265. doi: 10.3390/tomography10020020. Tomography. 2024. PMID: 38393288 Free PMC article.
MeSH terms