Objective: The positive impact of minimally invasive extracorporeal circuits (MiECC) on patient outcome is expected to be most evident in patients with limited physiologic reserves. Nevertheless, most studies have limited their use to low-risk patients undergoing myocardial revascularization. As such, there is little evidence to their benefit outside this patient population. We, therefore, set out to explore their potential benefit in octogenarians undergoing aortic valve replacement (AVR) with or without concomitant myocardial revascularization.
Methods: Based on the type of the utilized ECC, we performed a retrospective propensity score-matched comparison among all octogenarians (n = 218) who received a primary AVR with or without concomitant coronary artery bypass grafting in our institution between 2003 and 2010.
Results: A MiECC was utilized in 32% of the patients. The propensity score matching yielded 52 matched pairs. The 30-day postoperative mortality (2% vs. 10%; p=0.2), the incidence of low cardiac output (0% vs. 6%; p=0.2) and the Intensive Care Unit (ICU) stay (2.5 ± 2.6 vs. 3.8 ± 4.7 days; p=0.06) were all in favour of the MiECC group, but failed to reach statistical significance while the 90-day postoperative mortality did (2% vs. 16%; p=0.02).
Conclusion: MiECCs have a positive influence on the outcome of octogenarians undergoing AVR with or without concomitant coronary artery bypass grafting. Their use should, therefore, be extended beyond isolated coronary artery bypass graft (CABG) surgery.
Keywords: aortic valve replacement; cardiopulmonary bypass; coronary artery bypass grafting; minimally invasive extracorporeal circuits; octogenarians.
Similar articles
-
Impact of minimally invasive extracorporeal circuits on octogenarians undergoing coronary artery bypass grafting. Have we been looking in the wrong direction?Eur J Cardiothorac Surg. 2017 Dec 1;52(6):1175-1181. doi: 10.1093/ejcts/ezx156. Eur J Cardiothorac Surg. 2017. PMID: 28582490
-
Is aortic valve replacement with a minimally invasive extracorporeal circuit a contemporary option for octogenarians?Interact Cardiovasc Thorac Surg. 2020 Jul 1;31(1):56-62. doi: 10.1093/icvts/ivaa066. Interact Cardiovasc Thorac Surg. 2020. PMID: 32442258
-
Minimally invasive versus standard extracorporeal circulation system in minimally invasive aortic valve surgery: a propensity score-matched study.Eur J Cardiothorac Surg. 2020 Apr 1;57(4):717-723. doi: 10.1093/ejcts/ezz318. Eur J Cardiothorac Surg. 2020. PMID: 31746980
-
Return to work after coronary artery bypass grafting and aortic valve replacement surgery: A scoping review.Scand J Caring Sci. 2022 Dec;36(4):893-909. doi: 10.1111/scs.13006. Epub 2021 May 31. Scand J Caring Sci. 2022. PMID: 34057755
-
Minimally invasive cardiac surgery: a new frontier.Crit Care Nurs Q. 1998 May;21(1):16-23. doi: 10.1097/00002727-199805000-00005. Crit Care Nurs Q. 1998. PMID: 9644358 Review.
Cited by
-
Minimized extracorporeal circulation in non-coronary surgery.J Thorac Dis. 2019 Jun;11(Suppl 10):S1498-S1506. doi: 10.21037/jtd.2019.02.04. J Thorac Dis. 2019. PMID: 31293800 Free PMC article. Review.
-
Influence of minimal invasive extracorporeal circuits on dialysis dependent patients undergoing cardiac surgery.Perfusion. 2024 Nov;39(8):1708-1714. doi: 10.1177/02676591231216794. Epub 2023 Nov 17. Perfusion. 2024. PMID: 37977566 Free PMC article.
MeSH terms
LinkOut - more resources
Full Text Sources
Research Materials