Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2019 Jun;30(4):1049-1054.
doi: 10.1097/SCS.0000000000004795.

Dental Implants With a Platform-Switched Morse Taper Connection and an Osteo Growth Induction Surface

Affiliations

Dental Implants With a Platform-Switched Morse Taper Connection and an Osteo Growth Induction Surface

Paolo Ghensi et al. J Craniofac Surg. 2019 Jun.

Abstract

Aim: The aim of this study was to analyze the clinical outcomes after using an innovative implant system characterized by a modern platform-switched Morse taper connection and an osteo growth induction titanium surface (a particular type of SLA surface). Peri-implant bone loss (PBL) and implant success rate were examined after a 1- to 3-year follow-up.

Methods: The study was conducted as a cross-sectional analysis on all patients treated from January 2011 to December 2014 using CLC CONIC implants. Implants were divided into 3 main groups, based on the duration of the follow-up (1 year, 2 years, and 3 years), then subgrouped by diameter, length, and type of prosthetic rehabilitation to compare differences in PBL. X-rays were taken at the time of surgery, at prosthetic loading, at 1 year, and then annually thereafter. Previously-established success criteria were used to assess the implants. Frequency analyses and comparisons between the means (with 95% CI) were conducted for the statistical analysis of the data collected.

Results: One hundred twenty patients met inclusion and exclusion criteria, and completed the follow-up, and were thus eligible for the study, with a total of 261 CLC CONIC implants. The mean follow-up was 22.45 months. No implants failed, giving an overall success rate of 100%. The average PBL at 1-year follow-up was 0.047 mm, at 2 years it was 0.128 mm, and at 3 years it was 0.236 mm.

Conclusions: The CLC CONIC implant system had a high success rate after 1 to 3 years of follow-up, in line with previous reports in the scientific literature. Combining platform switching with the Morse taper connection enabled stable bone levels to be achieved in the short to medium term.

PubMed Disclaimer

Substances

LinkOut - more resources