Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 1987 Aug;61(2):228-35.
doi: 10.1161/01.res.61.2.228.

Hypoxia does not alter angiotensin converting enzyme activity in hamster pulmonary microvessels

Free article
Comparative Study

Hypoxia does not alter angiotensin converting enzyme activity in hamster pulmonary microvessels

J M Shepard et al. Circ Res. 1987 Aug.
Free article

Abstract

Studies were initiated to investigate the effects of hypoxia on the conversion of angiotensin I (AI) to angiotensin II (AII) in microvessels of the lung. Using the technique of allografting neonatal lung tissue into the cheek pouch of normal hamsters, the microvessels of the lung, pulmonary arterioles, and venules could be visualized and manipulated by direct in vivo microscopy. The microvessels of the lung were studied 7-10 days after allografting by anesthetizing the hamster with pentobarbital (6.0 mg/100 g body weight i.p.) and then preparing the lung tissue for observation. The tissue was suffused with a Ringer's bicarbonate solution bubbled with a normal (20% O2-5% CO2-75% N2) or a low (95% N2-5% CO2) oxygen mixture. After equilibration, a pulmonary arteriole or venule was selected for observation, and the vessel geometry was recorded. Then, a micropipette containing either AI or AII was positioned alongside the vessel, and the agent was delivered continuously for 2 minutes. Lumen diameter was recorded continually for 8-10 minutes. This procedure was repeated until both angiotensins were tested on pulmonary arterioles and venules under conditions of a normal and low oxygen environment. This protocol was repeated on cheek pouch microvessels that did not contain pulmonary allografts. Both AI and AII produced rapid decreases in the lumen diameters of all microvessels tested. This vasoconstriction was greater for AII, and the oxygen environment did not alter the response. Conversion of AI to AII was not altered by the oxygen environment, and the relative conversion was similar in the microvessels of the lung and cheek pouch.(ABSTRACT TRUNCATED AT 250 WORDS)

PubMed Disclaimer

Similar articles

Cited by

Publication types

MeSH terms

LinkOut - more resources