Videolaryngoscopy versus fiberoptic bronchoscope for awake intubation - a systematic review and meta-analysis of randomized controlled trials
- PMID: 30410341
- PMCID: PMC6197207
- DOI: 10.2147/TCRM.S172783
Videolaryngoscopy versus fiberoptic bronchoscope for awake intubation - a systematic review and meta-analysis of randomized controlled trials
Abstract
Background: Awake intubation with videolaryngoscopy (VL) is a novel method that is drawing more and more attention as an alternative to awake intubation with fiberoptic bronchoscope (FOB). This meta-analysis is designed to determine the performance of VL compared to the FOB for awake intubation.
Methods: The Cochrane Central Register of Controlled Trials, PubMed, Embase, and Web of science were searched from database inception until October 30, 2017. Randomized controlled trials comparing VL and FOB for awake intubation were selected. The primary outcome was the overall success rate. Rev-Man 5.3 software was used to perform the pooled analysis and assess the risk of bias for each eligible study. The GRADE system was used to assess the quality of evidence for all outcomes.
Results: Six studies (446 patients) were included in the review for data extraction. Pooled analysis did not show any difference in the overall success rate by using VL and FOB (relative risk [RR], 1.00; P=0.99; high-quality evidence). There was no heterogeneity among studies (I 2=0). Subgroup analyses showed no differences between two groups through nasal (RR, 1.00; P=1.00; high-quality evidence) and oral intubations (RR, 1.00; P=0.98; high-quality evidence). The intubation time was shorter by using VL than by using FOB (mean difference, -40.4 seconds; P<0.01; low-quality evidence). There were no differences between groups for other outcomes (P>0.05).
Conclusion: For awake intubation, VL with a shorter intubation time is as effective and safe as FOB. VL may be a useful alternative to FOB.
Keywords: airway management; awake intubation; fiberoptic bronchoscopy; outcomes; randomized controlled clinical trials; videolaryngoscopy.
Conflict of interest statement
Disclosure The authors report no conflicts of interest in this work.
Figures
References
-
- Schiff JH, Welker A, Fohr B, et al. Major incidents and complications in otherwise healthy patients undergoing elective procedures: results based on 1.37 million anaesthetic procedures. Br J Anaesth. 2014;113(1):109–121. - PubMed
-
- Shiima Y, Berg RA, Bogner HR, Morales KH, Nadkarni VM, Nishisaki A, National Emergency Airway Registry for Children Investigators Cardiac arrests associated with tracheal intubations in PICUs: a multicenter cohort study. Crit Care Med. 2016;44(9):1675–1682. - PubMed
-
- Apfelbaum JL, Hagberg CA, Caplan RA, et al. Practice guidelines for management of the difficult airway: an updated report by the American Society of Anesthesiologists Task Force on Management of the Difficult Airway. Anesthesiology. 2013;118(2):251–270. - PubMed
-
- Law JA, Morris IR, Brousseau PA, de La Ronde S, Milne AD. The incidence, success rate, and complications of awake tracheal intubation in 1,554 patients over 12 years: an historical cohort study. Can J Anaesth. 2015;62(7):736–744. - PubMed
LinkOut - more resources