Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Review
. 2018 Nov 8;10(4):221.
doi: 10.3390/pharmaceutics10040221.

A Review on Liquid Chromatography-Tandem Mass Spectrometry Methods for Rapid Quantification of Oncology Drugs

Affiliations
Review

A Review on Liquid Chromatography-Tandem Mass Spectrometry Methods for Rapid Quantification of Oncology Drugs

Andrea Li-Ann Wong et al. Pharmaceutics. .

Abstract

In the last decade, the tremendous improvement in the sensitivity and also affordability of liquid chromatography-tandem mass spectrometry (LC-MS/MS) has revolutionized its application in pharmaceutical analysis, resulting in widespread employment of LC-MS/MS in determining pharmaceutical compounds, including anticancer drugs in pharmaceutical research and also industries. Currently, LC-MS/MS has been widely used to quantify small molecule oncology drugs in various biological matrices to support preclinical and clinical pharmacokinetic studies in R&D of oncology drugs. This mini-review article will describe the state-of-the-art LC-MS/MS and its application in rapid quantification of small molecule anticancer drugs. In addition, efforts have also been made in this review to address several key aspects in the development of rapid LC-MS/MS methods, including sample preparation, chromatographic separation, and matrix effect evaluation.

Keywords: LC-MS/MS; oncology drugs; quantification; rapid.

PubMed Disclaimer

Conflict of interest statement

The authors declare no conflict of interest.

Figures

Figure 1
Figure 1
Pipeline for conducting bioanalysis using liquid chromatography-tandem mass spectrometry.
Figure 2
Figure 2
Distribution of sample preparation assays. PPT: protein precipitation; LLE: liquid-liquid extraction; SPE: solid phase extraction.
Figure 3
Figure 3
Run time (min) for determination of 1 analyte.
Figure 4
Figure 4
Run time (min) for determination of ≥2 analytes.
Figure 5
Figure 5
The schematic of the post-column infusion system for evaluation of matrix effects.

References

    1. Zhang H., Lin Y., Li K., Liang J., Xiao X., Cai J., Tan Y., Xing F., Mai J., Li Y., et al. Naturally Existing Oncolytic Virus M1 Is Nonpathogenic for the Nonhuman Primates After Multiple Rounds of Repeated Intravenous Injections. Hum. Gene Ther. 2016;27:700–711. doi: 10.1089/hum.2016.038. - DOI - PMC - PubMed
    1. Molina J.R., Yang P., Cassivi S.D., Schild S.E., Adjei A.A. Non-small cell lung cancer: Epidemiology, risk factors, treatment, and survivorship. Mayo Clin. Proc. 2008;83:584–594. doi: 10.1016/S0025-6196(11)60735-0. - DOI - PMC - PubMed
    1. Kola I., Landis J. Can the pharmaceutical industry reduce attrition rates? Nat. Rev. Drug Discov. 2004;3:711–715. doi: 10.1038/nrd1470. - DOI - PubMed
    1. Das S., Dubey R., Roychowdhury S., Ghosh M., Sinha B.N., Kumar Pradhan K., Bal T., Muthukrishnan V., Seijas J.A., Pujarid A. A rapid and sensitive determination of hypoxic radiosensitizer agent nimorazole in rat plasma by LC-MS/MS and its application to a pharmacokinetic study. Biomed. Chromatogr. 2015;29:1575–1580. doi: 10.1002/bmc.3461. - DOI - PubMed
    1. Sharma S., Dubey N.K., Dasgupta A.K., Sahu M., Benjamin B., Mullangi R., Srinivas N.R. Highly sensitive method for the determination of JI-101, a multi-kinase inhibitor in human plasma and urine by LC-MS/MS-ESI: Method validation and application to a clinical pharmacokinetic study. Biomed. Chromatogr. 2012;26:232–238. doi: 10.1002/bmc.1652. - DOI - PubMed

LinkOut - more resources