A Review on Liquid Chromatography-Tandem Mass Spectrometry Methods for Rapid Quantification of Oncology Drugs
- PMID: 30413076
- PMCID: PMC6321130
- DOI: 10.3390/pharmaceutics10040221
A Review on Liquid Chromatography-Tandem Mass Spectrometry Methods for Rapid Quantification of Oncology Drugs
Abstract
In the last decade, the tremendous improvement in the sensitivity and also affordability of liquid chromatography-tandem mass spectrometry (LC-MS/MS) has revolutionized its application in pharmaceutical analysis, resulting in widespread employment of LC-MS/MS in determining pharmaceutical compounds, including anticancer drugs in pharmaceutical research and also industries. Currently, LC-MS/MS has been widely used to quantify small molecule oncology drugs in various biological matrices to support preclinical and clinical pharmacokinetic studies in R&D of oncology drugs. This mini-review article will describe the state-of-the-art LC-MS/MS and its application in rapid quantification of small molecule anticancer drugs. In addition, efforts have also been made in this review to address several key aspects in the development of rapid LC-MS/MS methods, including sample preparation, chromatographic separation, and matrix effect evaluation.
Keywords: LC-MS/MS; oncology drugs; quantification; rapid.
Conflict of interest statement
The authors declare no conflict of interest.
Figures
References
-
- Zhang H., Lin Y., Li K., Liang J., Xiao X., Cai J., Tan Y., Xing F., Mai J., Li Y., et al. Naturally Existing Oncolytic Virus M1 Is Nonpathogenic for the Nonhuman Primates After Multiple Rounds of Repeated Intravenous Injections. Hum. Gene Ther. 2016;27:700–711. doi: 10.1089/hum.2016.038. - DOI - PMC - PubMed
-
- Das S., Dubey R., Roychowdhury S., Ghosh M., Sinha B.N., Kumar Pradhan K., Bal T., Muthukrishnan V., Seijas J.A., Pujarid A. A rapid and sensitive determination of hypoxic radiosensitizer agent nimorazole in rat plasma by LC-MS/MS and its application to a pharmacokinetic study. Biomed. Chromatogr. 2015;29:1575–1580. doi: 10.1002/bmc.3461. - DOI - PubMed
-
- Sharma S., Dubey N.K., Dasgupta A.K., Sahu M., Benjamin B., Mullangi R., Srinivas N.R. Highly sensitive method for the determination of JI-101, a multi-kinase inhibitor in human plasma and urine by LC-MS/MS-ESI: Method validation and application to a clinical pharmacokinetic study. Biomed. Chromatogr. 2012;26:232–238. doi: 10.1002/bmc.1652. - DOI - PubMed
Publication types
LinkOut - more resources
Full Text Sources
