Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2019 Sep;20(9):786-789.
doi: 10.1016/j.carrev.2018.10.023. Epub 2018 Oct 25.

The Left Distal Transradial Artery Access for Coronary Angiography and Intervention: A US Experience

Affiliations

The Left Distal Transradial Artery Access for Coronary Angiography and Intervention: A US Experience

Karim M Al-Azizi et al. Cardiovasc Revasc Med. 2019 Sep.

Abstract

Background: The radial artery is the access of choice in many catheterization labs around the world due to its proven benefits over the femoral artery access. There has been growing interest in the left radial artery. We sought to evaluate the feasibility, safety and complication rates of the left distal radial artery (ldTRA) access for cardiac catheterization.

Methods: This is a single arm retrospective study evaluating the feasibility and safety of performing cardiac catheterization through ldTRA. The procedure was completed using standard diagnostic and guiding catheters. Hemostasis was achieved with a radial band. Feasibility was the ability to cannulate the distal left radial artery as well as completing the procedure without requiring an additional arterial access. The safety point included hematoma, bleeding or neuropathy.

Results: ldTRA was attempted in 61 patients. 59 patients had successful completion of the procedure through ldTRA. Conversion occurred in 1 patient (1.7%), requiring an additional arterial access to complete the procedure. 34 patients (55.7%) required percutaneous coronary intervention (PCI). There was no access site bleeds post procedure, no hematomas, with 100% successful hemostasis with a radial hemostatic band. There were 2 cases requiring reaccess of the distal left radial artery access for repeat revascularization, with procedure success and good left radial artery patency.

Conclusion: ldTRA is a safe and feasible arterial access in a radial experienced catheterization lab. ldTRA provides improved operator ergonomics and patient's comfort, in addition to the advantage of being able to cannulate the bypass grafts and with a very low risk of vascular complications.

Keywords: Cardiac catheterization; Coronary angiography and intervention; Left distal trans-radial artery; Radial artery access; Snuff box technique.