Abstract

Background: The esthetics plays an increasingly significant role in today's dentistry.

Objective: The objective was to investigate the shade stability of a polymer-infiltrated and a resin nano ceramic in comparison to a conventional feldspar ceramic and an acrylate polymer.

Methods: 20 specimens of each of the materials, CAD-Temp (CT), Mark II (M), VITA Enamic (VE) and Lava Ultimate (LU), were prepared using the standard method. These were divided into groups (n=5) and placed in the following stain solutions: Distilled water, coffee, Coca-Cola and red wine for 14 days. The shade of each specimen was measured before and after using a spectrophotometer (n=5). The data were analyzed using ANOVA and Tukey's test (p ≤ 0.05).

Results: The largest ΔE mean values were observed in CT by Coca-Cola (4.38 ± 0.41), in M by coffee (5.95 ± 0.62), in VE (6.02 ± 0.78) and LU (8.61 ± 0.30) by red wine. LU had the largest and strongest overall shade differences (total score: SSC=16.95) and CT the least (SSC=8.74). Overall shade differences of VE (SSC=12.03) and M (SSC=12.48) were statistically indistinguishable. After 14 days, only Coca-Cola caused clinically relevant shade differences in CT (ΔE > 2.7); this was also caused by coffee, Coca-Cola and red wine in M and coffee and red wine in VE and LU.

Conclusion: On average, VE showed fewer shade differences than LU. After 14 days of immersion, shade differences which exceeded the clinical acceptance threshold of ΔE=2.7 were shown by CT in Coca-Cola, by M in coffee, Coca-Cola and red wine, and by VE and LU in coffee and red wine.

Keywords: Lava Ultimate; Polymer-infiltrated ceramic; Resin nano ceramic; Shade stability; Spectrophotometer; VITA Easyshade; VITA Enamic.

PubMed Disclaimer

Figures

Fig. (1)
Fig. (1)
Fig. (2)
Fig. (2)
Fig. (3)
Fig. (3)
Fig. (4)
Fig. (4)
Fig. (5)
Fig. (5)
Fig. (6)
Fig. (6)

References

    1. Bilhan H., Bural C., Geckili O. Titanium hypersensitivity: A hidden threat for dental implant patients? N. Y. State Dent. J. 2013;79(4):38–43. - PubMed
    1. Norman C. Zusammenstellung wissenschaftlicher Ergebnisse Lava Ultimate CAD/CAM Restaurations material. Espertise. 2014. pp. 1–56.
    1. Baumgart P.S., Haak R., Olms C. Surface wear of polymer-infiltrated dental ceramic on one-piece zirconia implants after long-term chewing simulation. Z Zahnärztl Impl. 2017;33:138–142. - PMC - PubMed
    1. Seidemann M., Haak R., Olms C. A Pilot study for evaluating interfaces by OCT: Loading of a Resin Nano Ceramic on one-piece ZrO2 implants. Z Zahnärztl Impl. 2017;33:202–211.
    1. Della Bona A., Corazza P.H., Zhang Y. Characterization of a polymer-infiltrated ceramic-network material. Dent. Mater. 2014;30(5):564–569. doi: 10.1016/j.dental.2014.02.019. - DOI - PMC - PubMed

LinkOut - more resources