Using Resonance Frequency Analysis to Compare Delayed and Immediate Progressive Loading for Implants Placed in the Posterior Maxilla: A Pilot Study

Affiliations

Using Resonance Frequency Analysis to Compare Delayed and Immediate Progressive Loading for Implants Placed in the Posterior Maxilla: A Pilot Study

Mohammed Jasim Al Juboori et al. Open Dent J. .

Abstract

Objective: Implants placed in the posterior region of the maxilla have a high incidence of implant failure due to poor bone quality, especially when immediate implant loading is needed. Immediate Progressive Loading (IPL) can enhance bone quality and may offer an alternative solution when Immediate Implant loading is needed.

Methods: Six patients (one male and five females; 34-62 years old) were included in this study. Twelve implants were inserted in the posterior region of the maxilla. Resonance Frequency Analysis (RFA) was performed at the time of implant placement and after 1, 2, 3 and 6 months. ISQ (Implant Stability Quotient) values were compared between the Delayed Loading (DL) group after 2 months and the Progressive Loading (PL) group and between different time points for each group.

Results: At implant placement, the mean ISQ values for PL and DL implants were 63 and 57, respectively. One month after implant placement, the mean ISQ value for PL implants was 73.Two months after implant placement, the mean ISQ value for PL implants was 75. Three months after implant placement, the mean ISQ values for PL and DL implants were 76 and 69, respectively. Six months after implant placement, the mean ISQ values for PL and DL implants were 79 and 76, respectively.

Conclusion: Despite its limitations, this pilot study indicated that compared to DL, PL can enhance bone density and implant stability, resulting in greater early functionality and fewer surgery sessions.

Keywords: Bone density; Bone-Implant Contact (BIC); Implant stability; Maxillary bone; Provisional crown; Resonance Frequency Analysis (RFA).

PubMed Disclaimer

Figures

Fig. (1)
Fig. (1)
Fig. (2)
Fig. (2)
Fig. (3)
Fig. (3)
Fig. (4)
Fig. (4)
Fig. (5)
Fig. (5)

Similar articles

Cited by

References

    1. Lekholm U., Zarb G. Patient selection and preparation. In: Bffmemark P-I., Zarb G., Albrektsson T., editors. Tissue-integrated prosthesis: Osseointegration in clinical dentistry. Chi- cago: Quintessence. 1985. pp. 199–209.
    1. Bischof M., Nedir R., Szmukler-Moncler S., Bernard J.P., Samson J. Implant stability measurement of delayed and immediately loaded implants during healing. Clin. Oral Implants Res. 2004;15(5):529–539. doi: 10.1111/j.1600-0501.2004.01042.x. - DOI - PubMed
    1. Mesa F., Muñoz R., Noguerol B., de Dios Luna J., Galindo P., O’Valle F. Multivariate study of factors influencing primary dental implant stability. Clin. Oral Implants Res. 2008;19(2):196–200. doi: 10.1111/j.1600-0501.2007.01450.x. - DOI - PubMed
    1. Lorenzoni M., Pertl C., Zhang K., Wegscheider W.A. In-patient comparison of immediately loaded and non-loaded implants within 6 months. Clin. Oral Implants Res. 2003;14(3):273–279. doi: 10.1034/j.1600-0501.2003.140304.x. - DOI - PubMed
    1. Jaffin R.A., Berman C.L. The excessive loss of Branemark fixtures in type IV bone: A 5-year analysis. J. Periodontol. 1991;62(1):2–4. doi: 10.1902/jop.1991.62.1.2. - DOI - PubMed

LinkOut - more resources