Visual Performance of Daily-disposable Multifocal Soft Contact Lenses: A Randomized, Double-blind Clinical Trial
- PMID: 30451806
- DOI: 10.1097/OPX.0000000000001311
Visual Performance of Daily-disposable Multifocal Soft Contact Lenses: A Randomized, Double-blind Clinical Trial
Abstract
Significance: The present study highlights the differences between modern daily-disposable multifocal soft contact lenses to assist eye care practitioners in fitting presbyopic contact lens wearers.
Purpose: The purpose of this study was to compare visual performance of three daily-disposable multifocal contact lenses.
Methods: Presbyopes (n = 72) wore 1-Day Acuvue Moist Multifocal, BioTrue ONEday for Presbyopia, and Dailies AquaComfort Plus Multifocal for 1 week in a prospective, randomized, double-blind, crossover clinical trial. After 1 week, high- and low-contrast visual acuities (HCVA, LCVA) were measured between 6 m and 40 cm and stereopsis at 40 cm. Subjective performance was assessed with 1- to 10-point rating scales for clarity, ghosting, driving vision, vision stability, ease of focusing, overall vision satisfaction, and ocular comfort. Willingness to purchase was reported with categorical responses. Linear mixed models and χ tests were used for analysis, and level of significance was set at 5%.
Results: BioTrue provided better HCVA and LCVA at distance than did Acuvue Moist (P ≤ .03). Subjectively, Acuvue Moist was rated lowest for distance clarity, distance ghosting, and driving vision (P ≤ .05). Acuvue Moist provided better HCVA at 70 to 40 cm and LCVA at 1 m to 40 cm than did BioTrue (P ≤ .01) and better LCVA at 1 m to 50 cm than did AquaComfort Plus (P ≤ .02). AquaComfort Plus also provided better HCVA and LCVA at 50 and 40 cm than did BioTrue (P ≤ .03). Acuvue Moist provided better stereopsis than did BioTrue (P = .02). Subjectively, BioTrue was rated lowest for near clarity (P ≤ .007) and lower than Acuvue Moist for intermediate clarity and near ghosting (P ≤ .04). No other differences were found between lenses (P > .05).
Conclusions: BioTrue had better distance performance compared with near, whereas Acuvue Moist performed conversely. AquaComfort Plus performed reasonably overall.
Trial registration: ClinicalTrials.gov NCT02484586.
Similar articles
-
Short-Term Visual Performance of Novel Extended Depth-of-Focus Contact Lenses.Optom Vis Sci. 2016 Apr;93(4):435-44. doi: 10.1097/OPX.0000000000000806. Optom Vis Sci. 2016. PMID: 26808384 Clinical Trial.
-
Short-term visual performance of soft multifocal contact lenses for presbyopia.Arq Bras Oftalmol. 2016 Apr;79(2):73-7. doi: 10.5935/0004-2749.20160023. Arq Bras Oftalmol. 2016. PMID: 27224066 Clinical Trial.
-
Comparison of Extended Depth-of-Focus Prototype Contact Lenses With the 1-Day ACUVUE MOIST MULTIFOCAL After One Week of Wear.Eye Contact Lens. 2018 Nov;44 Suppl 2:S157-S163. doi: 10.1097/ICL.0000000000000430. Eye Contact Lens. 2018. PMID: 29023311 Clinical Trial.
-
Presbyopic contact lenses.Curr Opin Ophthalmol. 2000 Aug;11(4):296-8. doi: 10.1097/00055735-200008000-00012. Curr Opin Ophthalmol. 2000. PMID: 10977775 Review.
-
Contact lens correction of presbyopia.Clin Exp Optom. 2008 May;91(3):265-78. doi: 10.1111/j.1444-0938.2007.00242.x. Epub 2008 Jan 8. Clin Exp Optom. 2008. PMID: 18201225 Review.
Cited by
-
Pilot Study Evaluating the Early Clinical Outcomes Obtained with a Novel, Customized, Multifocal Corneo-Scleral Contact Lens for Presbyopia Correction.Life (Basel). 2025 Apr 25;15(5):700. doi: 10.3390/life15050700. Life (Basel). 2025. PMID: 40430129 Free PMC article.
-
Efficacy of a new refractive multifocal contact lens for presbyopia.Sci Rep. 2024 Apr 17;14(1):8878. doi: 10.1038/s41598-024-55918-5. Sci Rep. 2024. PMID: 38632261 Free PMC article.
-
Classification of Presbyopia by Severity.Ophthalmol Ther. 2022 Feb;11(1):1-11. doi: 10.1007/s40123-021-00410-w. Epub 2021 Oct 28. Ophthalmol Ther. 2022. PMID: 34709607 Free PMC article.
-
Multifocal versus modified monovision corrections: A non-dispensing comparison of visual assessment in presbyopic neophytes.Indian J Ophthalmol. 2023 May;71(5):1837-1842. doi: 10.4103/ijo.IJO_2027_22. Indian J Ophthalmol. 2023. PMID: 37203039 Free PMC article.
-
Role of improved distance and near visual acuity with low vision aids to enhance stereopsis in retinal diseases.Indian J Ophthalmol. 2021 Jul;69(7):1867-1871. doi: 10.4103/ijo.IJO_3154_20. Indian J Ophthalmol. 2021. PMID: 34146046 Free PMC article.
Publication types
MeSH terms
Associated data
LinkOut - more resources
Full Text Sources
Medical