Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2019 Jun;19(5):645-652.
doi: 10.1080/17461391.2018.1546338. Epub 2018 Nov 19.

3-min all-out effort on cycle ergometer is valid to estimate the anaerobic capacity by measurement of blood lactate and excess post-exercise oxygen consumption

Affiliations
Free article

3-min all-out effort on cycle ergometer is valid to estimate the anaerobic capacity by measurement of blood lactate and excess post-exercise oxygen consumption

Alessandro Moura Zagatto et al. Eur J Sport Sci. 2019 Jun.
Free article

Abstract

The purpose of this study was to investigate the use of a single 3-min all-out maximal effort to estimate anaerobic capacity (AC) through the lactate and excess post-exercise oxygen consumption (EPOC) response methods (AC[La-]+EPOCfast) on a cycle ergometer. Eleven physically active men (age = 28.1 ± 4.0 yrs, height = 175.1 ± 4.2 cm, body mass = 74.8 ± 11.9 kg and ⩒O2max = 40.7 ± 7.3 mL kg-1 min-1), participated in the study and performed: i) five submaximal efforts, ii) a supramaximal effort at 115% of intensity of ⩒O2max, and iii) a 3-min all-out maximal effort. Anaerobic capacity was estimated using the supramaximal effort through conventional maximal accumulated oxygen deficit (MAOD) and also through the sum of oxygen equivalents from the glycolytic (fast component of excess post-exercise oxygen consumption) and phosphagen pathways (blood lactate accumulation) (AC[La-]+EPOCfast), while during the 3-min all-out maximal effort the anaerobic capacity was estimated using the AC[La-]+EPOCfast procedure. There were no significant differences between the three methods (p > 0.05). Additionally, the anaerobic capacity estimated during the 3-min all-out effort was significantly correlated with the MAOD (r = 0.74; p = 0.009) and AC[La-]+EPOCfast methods (r = 0.65; p = 0.029). Therefore, it is possible to conclude that the 3-min all-out effort is valid to estimate anaerobic capacity in physically active men during a single cycle ergometer effort.

Keywords: Anaerobic capacity; all-out efforts; cycle exercise; excess post-exercise oxygen consumption; maximal accumulated oxygen deficit.

PubMed Disclaimer

Publication types

LinkOut - more resources