Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Randomized Controlled Trial
. 2019 May;51(5):436-443.
doi: 10.1055/a-0757-7714. Epub 2018 Nov 19.

19 G nitinol needle versus 22 G needle for transduodenal endoscopic ultrasound-guided sampling of pancreatic solid masses: a randomized study

Affiliations
Randomized Controlled Trial

19 G nitinol needle versus 22 G needle for transduodenal endoscopic ultrasound-guided sampling of pancreatic solid masses: a randomized study

Arthur Laquière et al. Endoscopy. 2019 May.

Abstract

Background: The aim of this prospective multicenter study was to compare a flexible 19 G needle with nitinol shaft (19 G Flex) with a standard 22 G needle for transduodenal endoscopic ultrasound (EUS)-guided sampling of pancreatic head tumors.

Methods: Patients with pancreatic head tumors requiring tissue diagnosis were randomized into two arms: puncture with either a 19 G Flex needle or a 22 G needle. The primary end point was diagnostic accuracy for malignancy. The secondary end points were ergonomic scores, sample cytohistological quality, and complications. A 6-month follow-up was performed.

Results: 125 patients were randomized and 122 were analyzed: 59 patients in the 19 G Flex arm and 63 patients in the 22 G arm. The final diagnosis was malignancy in 111 patients and benign condition in 11. In intention-to-treat analysis, the diagnostic accuracy for malignancy of the 19 G Flex and 22 G needles was 69.5 % (95 % confidence interval [CI] 56.1 % - 80.8 %) vs. 87.3 % (95 %CI 76.5 % - 94.4 %), respectively (P = 0.02). In per-protocol analysis excluding eight technical failures in the 19 G Flex group, the diagnostic accuracy of the 19 G Flex and 22 G needles was not statistically different: 80.4 % (95 %CI 66.9 % - 90.2 %) vs. 87.3 % (95 %CI 76.5 % - 94.4 %; P = 0.12). Technical success was higher in the 22 G arm than in the 19 G Flex arm: 100 % (95 %CI 94.3 % - 100 %) vs. 86.4 % (95 %CI 75.0 % - 94.0 %), respectively (P = 0.003). Transduodenal EUS-guided sampling was more difficult with the 19 G Flex (odds ratio 0.68, 95 %CI 0.47 - 0.97). CONCLUSION : The 19 G Flex needle was inferior to a standard 22 G needle in diagnosing pancreatic head cancer and more difficult to use in the transduodenal approach.

Trial registration: ClinicalTrials.gov NCT02078232.