. 2019 Mar 1;74(3):787-790.
doi: 10.1093/jac/dky474.

Intravenous catheter-related adverse events exceed drug-related adverse events in outpatient parenteral antimicrobial therapy

Affiliations

Intravenous catheter-related adverse events exceed drug-related adverse events in outpatient parenteral antimicrobial therapy

Jonathan Underwood et al. J Antimicrob Chemother. .

Abstract

Background: Drug-related adverse events (AEs) are reported to be common amongst patients receiving outpatient parenteral antimicrobial therapy (OPAT). However, comparative data regarding intravenous (iv) catheter-related AEs are lacking.

Objectives: To compare drug- and iv catheter-related AEs from a large UK OPAT centre.

Patients and methods: We reviewed 544 OPAT episodes [median (IQR) age: 57 (39-71) years, 60% male, 13% with diabetes] with a median (IQR) duration of 7 (2-18) days. Clinically significant drug- and iv catheter-related AEs were calculated as a percentage of OPAT episodes with an AE and also as AEs per 1000 iv drug/catheter days.

Results: Drug-related AEs complicated 13 (2.4%) OPAT episodes at 1.7 (95% CI 0.9-2.9) per 1000 drug days. Catheter-related AEs occurred more frequently, complicating 32 (5.9%) episodes at 5.7 (95% CI 4.2-7.9) per 1000 iv catheter days (χ2 test for difference in AE rate: P < 0.001). Non-radiologically guided midline catheters were associated with the most frequent AEs (n = 23) at 15.6 (95% CI 10.3-23.4) per 1000 iv catheter days compared with other types of iv catheters (HR 8.4, 95% CI 2.4-51.9, P < 0.004), and self-administration was associated with a higher rate of catheter-related AEs at 12.0 (95% CI 6.0-23.9) per 1000 iv catheter days (HR 4.15, 95% CI 1.7-9.1, P = 0.007).

Conclusions: Clinically significant iv catheter-related AEs occurred more frequently than drug-related AEs, especially when using non-radiologically guided midline catheters. Regular review of the need for iv therapy and switching to oral antimicrobials when appropriate is likely to minimize OPAT-related AEs.

PubMed Disclaimer

Figures

Figure 1.
Figure 1.
Rate of OPAT-related AEs. Kaplan–Meier plots demonstrating (a) AEs attributed to either drugs or iv catheters and (b) catheter-related AEs stratified by route of iv access. AEs are indicated by censored events on plots.

References

    1. Mitchell ED, Czoski Murray C, Meads D. et al. Clinical and cost-effectiveness, safety and acceptability of community intravenous antibiotic service models: CIVAS systematic review. BMJ Open 2017; 7: e013560. - PMC - PubMed
    1. Gilchrist M, Seaton RA.. Outpatient parenteral antimicrobial therapy and antimicrobial stewardship: challenges and checklists. J Antimicrob Chemother 2015; 70: 965–70. - PubMed
    1. Ponce González MA, Mirón Rubio M, Mujal Martinez A. et al. Effectiveness and safety of outpatient parenteral antimicrobial therapy in acute exacerbation of chronic obstructive pulmonary disease. Int J Clin Pract 2017; 71: doi:10.1111/ijcp.13022. - DOI - PubMed