Investigation of the relation between administered dose and image quality for pediatric 99mTc-DMSA renal scintigraphy: clinical study applying the JSNM (Japanese Society of Nuclear Medicine) pediatric dosage card : The Japanese Society of Nuclear Medicine Technology (JSNMT), the Optimization of Imaging Technique Committee for Pediatric Nuclear Medicine Studies
- PMID: 30484259
- DOI: 10.1007/s12149-018-1320-6
Investigation of the relation between administered dose and image quality for pediatric 99mTc-DMSA renal scintigraphy: clinical study applying the JSNM (Japanese Society of Nuclear Medicine) pediatric dosage card : The Japanese Society of Nuclear Medicine Technology (JSNMT), the Optimization of Imaging Technique Committee for Pediatric Nuclear Medicine Studies
Abstract
Purpose: In 2013, the Japanese Society of Nuclear Medicine (JSNM) announced consensus guidelines for pediatric nuclear medicine. These JSNM guidelines proposed use of lower administered doses compared with traditionally determined doses, which were estimated from age, weight or body surface area (BSA) based on the administered dose for adults in Japan. When the JSNM guidelines are used, the relationship between this recommended administered dose and image quality remains unclear. In this study, we clarified the relationship between administered dose and image quality for pediatric 99mTc-DMSA renal scan retrospectively, and verified the diagnosable image quality with the recommended administered dose of the JSNM guidelines.
Materials and methods: Data from 7 pediatric patients who underwent 99mTc-DMSA dynamic renal scans according to the guidelines' recommended doses were collected. Scan frame rate was 1 frame/min, and scan time was up to 8 min. Eight images, which had different acquired time periods from 1 min to 8 min were prepared by adding each frame. Nine nuclear medicine specialists determined 8 images with different acquired times as diagnosable or undiagnosable. A region of interest (ROI) with 50% thresholds was placed on each kidney of every image. Coefficient of variation (CV) was calculated by dividing the standard deviation (σ) by the mean counts (µ) of each ROI (CV = σ/µ × 100). 99mTc-DMSA renal scans (total of 2821 cases) that were performed previously in collaboration with 6 hospitals were collected, and CVs of these images were calculated in all cases. These 2821 cases were separated into 5 groups for every 10 kg weight; i.e., (1) less than 10 kg, (2) 10-19.9 kg, (3) 20-29.9 kg, (4) 30-39.9 kg, and (5) above 40 kg. Regression line of each group was analyzed in relation to the CV and administered dose. The CV at the point of intersection with the recommended dose range from the guideline was determined for each group. This CV value was considered as the estimated CV of the image obtained when the recommended dose of the guideline was used. Thus, if the CV was equal to or less than the estimated CV value, then the diagnostic image quality was deemed satisfactory.
Results: Average CV of the lower limit of diagnosable images in 7 cases as determined by 9 nuclear medicine specialists was 19.9%. Estimated CV was 21.2-24.2% in the group weighing < 10 kg (group 1), 19.9-20.6% in the group weighing > 10 kg and < 20 kg (group 2), 19.6% in group weighing > 20 kg and < 30 kg (group 3), 19.4-19.5% in the group weighing > 30 kg and < 40 kg (group 4), and 19.8% in the group weighing > 40 kg (group 5). The estimated CVs from groups 1 and 2 with weight < 20 kg exceeded 19.9%.
Conclusions: Although 99mTc-DMSA renal scan can be carried out using the guidelines' recommended dose with conventional image acquisition time in patients weighing 20 kg or more, those < 20 kg need consideration for a longer image acquisition time to obtain diagnosable images.
Keywords: 99mTc-DMSA; Dosage card; JSNM; Pediatric; Renal.
Similar articles
-
Evaluation of 99mTc-succimer dosing in pediatric patients.J Nucl Med Technol. 2013 Jun;41(2):81-4. doi: 10.2967/jnmt.112.118836. Epub 2013 Apr 22. J Nucl Med Technol. 2013. PMID: 23608072
-
Weight-based determination of administered activity in 99mTc-DMSA renal SPECT in infants: are minimum administered activities necessary?Pediatr Radiol. 2025 Apr;55(4):866-874. doi: 10.1007/s00247-024-06155-5. Epub 2025 Feb 11. Pediatr Radiol. 2025. PMID: 39934452
-
Technetium-99m-N,N-ethylenedicysteine and Tc-99m DMSA scintigraphy in the evaluation of renal parenchymal abnormalities in children.Ann Nucl Med. 2003 May;17(3):219-25. doi: 10.1007/BF02990025. Ann Nucl Med. 2003. PMID: 12846544 Clinical Trial.
-
Consensus on renal cortical scintigraphy in children with urinary tract infection. Scientific Committee of Radionuclides in Nephrourology.Semin Nucl Med. 1999 Apr;29(2):160-74. doi: 10.1016/s0001-2998(99)80006-3. Semin Nucl Med. 1999. PMID: 10321827 Review.
-
Review of the Clinical and Technical Aspects of 99mTc-Dimercaptosuccinic Acid Renal Imaging: The Comeback "Kit".J Nucl Med Technol. 2024 Sep 5;52(3):199-204. doi: 10.2967/jnmt.123.267185. J Nucl Med Technol. 2024. PMID: 39137980 Review.
Cited by
-
Usefulness of preset count acquisition in pediatric 99m Tc-DMSA planar imaging.Ann Nucl Med. 2023 Aug;37(8):470-477. doi: 10.1007/s12149-023-01849-6. Epub 2023 Jun 12. Ann Nucl Med. 2023. PMID: 37306918
-
Acquisition time reduction in pediatric 99m Tc-DMSA planar imaging using deep learning.J Appl Clin Med Phys. 2023 Jun;24(6):e13978. doi: 10.1002/acm2.13978. Epub 2023 Apr 5. J Appl Clin Med Phys. 2023. PMID: 37021382 Free PMC article.
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical