Effect of increasing heart rate on finger photoplethysmography fitness index (PPGF) in subjects with implanted cardiac pacemakers
- PMID: 30485318
- PMCID: PMC6261569
- DOI: 10.1371/journal.pone.0207301
Effect of increasing heart rate on finger photoplethysmography fitness index (PPGF) in subjects with implanted cardiac pacemakers
Abstract
Finger photoplethysmography (PPG) is a noninvasive method that measures blood volume changes in the finger. The PPG fitness index (PPGF) has been proposed as an index of vascular risk and vascular aging. The objectives of the study were to determine the effects of heart rate (HR) on the PPGF and to determine whether PPGF is influenced by blood pressure (BP) changes. Twenty subjects (78±8 years, 3 female) with permanent cardiac pacemakers or cardioverter defibrillators were prospectively recruited. HR was changed by pacing, in a random order from 60 to 100 bpm and in 10 bpm increments. At each paced HR, the PPGF was derived from a finger photoplethysmogram. Cardiac output (CO), stroke volume (SV) and total peripheral resistance (TPR) were derived from the finger arterial pressure waveform. Brachial blood pressure (BP) was measured by the oscillometric method. This study found that as HR was increased from 60 to 100 bpm, brachial diastolic BP, brachial mean BP and CO were significantly increased (p<0.01), whilst the PPGF and SV were significantly decreased (p<0.001). The effects of HR on the PPGF were influenced by BP, with a decreasing HR effect on the PPGF that resulted from a higher BP. In conclusion, HR was a significant confounder for PPGF and it must be taken into account in analyses of PPGF, when there are large changes or differences in the HR. The magnitude of this effect was BP dependent.
Conflict of interest statement
The authors have declared that no competing interests exist.
Figures
References
-
- Allen J. Photoplethysmography and its application in clinical physiological measurement. Physiol Meas. 2007; 28(3): R1–R39. 10.1088/0967-3334/28/3/R01 - DOI - PubMed
-
- Allen J, Murray A. Age-related changes in peripheral pulse timing characteristics at the ears, fingers and toes. J Hum Hypertens. 2002; 16(10): 711–717. 10.1038/sj.jhh.1001478 - DOI - PubMed
-
- Takada H, Washino K, Harrell JS, Iwata H. Acceleration plethysmography to evaluate aging effect in cardiovascular system. Using new criteria of four wave patterns. Med Prog Technol. 1996–1997; 21(4): 205–210, - PubMed
-
- Chellappan K, Ali MAM, Zahedi E. An Age Index for Vascular System Based on Photoplethysmogram Pulse Contour Analysis. In: 4th Kuala Lumpur International Conference on Biomedical Engineering 2008 (pp. 125–128). Springer Berlin Heidelberg, 2008.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical