Magnitude dependent discordance in liver stiffness measurements using elastography point quantification with transient elastography as the reference test
- PMID: 30488108
- DOI: 10.1007/s00330-018-5831-2
Magnitude dependent discordance in liver stiffness measurements using elastography point quantification with transient elastography as the reference test
Abstract
Objectives: To investigate diagnostic performance of point shear wave elastography by elastography point quantification (ElastPQ) for non-invasive assessment of liver fibrosis in patients with chronic liver diseases (CLD).
Methods: Liver stiffness measurement (LSM) by transient elastography (TE) and ElastPQ was performed in patients with CLD and healthy volunteers. The stage of liver fibrosis was defined by TE which served as the reference. We compared two methods by using correlation, area under the receiver operating characteristics curve (AUC) analysis, Bland and Altman plot and Passing-Bablok regression.
Results: A total of 185 subjects (20 healthy volunteers and 165 patients with CLD (128 non-alcoholic fatty liver disease), 83 (44.9%) females, median age 53 years, BMI 27.3 kg/m2) were evaluated. There were 24.3%, 13.5% and 11.4% patients in ≥ F2, ≥ F3 and F4 stage, respectively. The best performing cutoff LSM values by ElastPQ were 5.5 kPa for F ≥ 2 (AUC = 0.96), 8.1 kPa for F ≥ 3 (AUC = 0.98) and 9.9 kPa for F4 (AUC = 0.98). Mean (SD) difference between TE and ElastPQ measurements was 0.98 (3.27) kPa (95% CI 0.51-1.45, range 4.99-21.60 kPa). Two methods correlated significantly (r = 0.86; p < 0.001), yet Bland and Altman plot demonstrated difference between measurements, especially with TE values > 10 kPa. Passing and Bablok regression analysis yielded significant constant and proportional difference between ElastPQ and TE.
Conclusion: ElastPQ is reliable method for assessment of liver fibrosis but LSM values are not interchangeable with TE, especially above 10 kPa. Diagnostic performance of ElastPQ for sub-classification of patients with compensated advanced chronic liver disease should therefore be furtherly investigated.
Key points: • ElastPQ appears to be reliable method for assessment of liver fibrosis, with data presented here mostly applicable to NAFLD. • LSM values produced by TE and ElastPQ are NOT interchangeable-in values < 10 kPa, they are similar, but in values > 10 kPa, they appear to be increasingly and significantly different. • Diagnostic performance of ElastPQ for sub-classification of patients with compensated advanced chronic liver disease should be furtherly investigated.
Keywords: Diagnostic performance; Liver fibrosis; Liver stiffness measurement; Non-alcoholic fatty liver disease.
Similar articles
-
Non-invasive Assessment of Liver Fibrosis with ElastPQ: Comparison with Transient Elastography and Serologic Fibrosis Marker Tests, and Correlation with Liver Pathology Results.Ultrasound Med Biol. 2017 Nov;43(11):2515-2521. doi: 10.1016/j.ultrasmedbio.2017.07.008. Epub 2017 Aug 26. Ultrasound Med Biol. 2017. PMID: 28844464
-
Comparison of point-shear wave elastography (ElastPQ) and transient elastography (FibroScan) for liver fibrosis staging in patients with non-alcoholic fatty liver disease.Liver Int. 2022 Oct;42(10):2195-2203. doi: 10.1111/liv.15297. Epub 2022 Jun 15. Liver Int. 2022. PMID: 35635761
-
Assessment of liver fibrosis with elastography point quantification technique in chronic hepatitis B virus patients: a comparison with liver pathological results.J Gastroenterol Hepatol. 2014 Apr;29(4):814-9. doi: 10.1111/jgh.12479. J Gastroenterol Hepatol. 2014. PMID: 24325607
-
Imaging-based noninvasive liver disease assessment for staging liver fibrosis in chronic liver disease: A systematic review supporting the AASLD Practice Guideline.Hepatology. 2025 Feb 1;81(2):725-748. doi: 10.1097/HEP.0000000000000852. Epub 2024 Mar 15. Hepatology. 2025. PMID: 38489521
-
Diagnostic accuracy of point shear wave elastography and transient elastography for staging hepatic fibrosis in patients with non-alcoholic fatty liver disease: a meta-analysis.BMJ Open. 2018 Aug 23;8(8):e021787. doi: 10.1136/bmjopen-2018-021787. BMJ Open. 2018. PMID: 30139901 Free PMC article. Review.
Cited by
-
Compensated Advanced Chronic Liver Disease and Steatosis in Patients with Type 2 Diabetes as Assessed through Shear Wave Measurements and Attenuation Measurements.Biomedicines. 2024 Jan 30;12(2):323. doi: 10.3390/biomedicines12020323. Biomedicines. 2024. PMID: 38397925 Free PMC article.
-
Point Shear Wave Elastography by ElastPQ for Fibrosis Screening in Patients with NAFLD: A Prospective, Multicenter Comparison to Vibration-Controlled Elastography.Ultraschall Med. 2023 Apr;44(2):169-178. doi: 10.1055/a-1724-7289. Epub 2022 Feb 28. Ultraschall Med. 2023. PMID: 35226932 Free PMC article.
-
The Role of Transabdominal Ultrasound Elastography in Gastrointestinal Non-Liver Diseases: Current Application and Future Prospectives.Diagnostics (Basel). 2023 Jul 4;13(13):2266. doi: 10.3390/diagnostics13132266. Diagnostics (Basel). 2023. PMID: 37443663 Free PMC article. Review.
-
Understanding confounding factors allows for accurate interpretation of liver stiffness measurements by ElastQ, a novel 2D shear wave elastography technique.Ultraschall Med. 2025 Aug;46(4):363-371. doi: 10.1055/a-2329-2801. Epub 2024 Aug 8. Ultraschall Med. 2025. PMID: 39117313 Free PMC article.