Assessment of S values for I131 and Y90 based on the Digimouse voxel phantom
- PMID: 30488847
- DOI: 10.4103/0973-1482.191058
Assessment of S values for I131 and Y90 based on the Digimouse voxel phantom
Abstract
Introduction: Most preclinical studies using radiopharmaceuticals have been carried out on mice. In nuclear medicine and radioimmunotherapy procedures, I131 and Y90 have been widely used. For better estimation of doses from these procedures, S value plays a vital role. In this study, we have evaluated S values for major source and target combinations of Digimouse voxel phantom.
Materials and methods: We have used the Digimouse voxel phantom which was incorporated in Monte Carlo code FLUKA. Simulation studies were performed using Monte Carlo simulation code FLUKA. Latest publication of International Commission on Radiological Protection (ICRP) report 110 was used for assigning the values of organ compositions and densities. Photon and electron spectra for I131 and Y90 have been taken from the ICRP publication 107. For Digimouse voxel phantom, we have simulated 9 source regions with an assumed uniform distribution of I131 and Y90.
Results and discussion: S values have been evaluated for I131 and Y90 for different source and target combinations of Digimouse voxel phantom and presented in tabular form. The S values can be applied prospectively or retrospectively to the calculation of radiation doses internally exposed to I131 and Y90, including nuclear medicine and radioimmunotherapy procedures. These S values have been very important for the calculation of absorbed doses for various organs similar in size to present study for mice.
Conclusion: In this study S value for I131 and Y90 were evaluated for major organs of digimouse voxel phantom. These S values are very important for absorbed dose calculation for various organs of a mouse.
Keywords: Digimouse voxel phantom; Monte Carlo simulation; S values.
Conflict of interest statement
There are no conflicts of interest
Similar articles
-
Evaluation of Electron Specific Absorbed Fractions in Organs of Digimouse Voxel Phantom Using Monte Carlo Simulation Code FLUKA.J Biomed Phys Eng. 2019 Apr 1;9(2):161-166. eCollection 2019 Apr. J Biomed Phys Eng. 2019. PMID: 31214521 Free PMC article.
-
Estimation of Photon Specific Absorbed Fractions in Digimouse Voxel Phantom using Monte Carlo Simulation Code FLUKA.J Biomed Phys Eng. 2016 Dec 1;6(4):209-216. eCollection 2016 Dec. J Biomed Phys Eng. 2016. PMID: 28144589 Free PMC article.
-
S values for 131I based on the ICRP adult voxel phantoms.Radiat Prot Dosimetry. 2016 Jan;168(1):92-110. doi: 10.1093/rpd/ncv016. Epub 2015 Mar 31. Radiat Prot Dosimetry. 2016. PMID: 25829162 Free PMC article.
-
Dose coefficients of ICRP adult reference voxel phantom for internal dosimetry of selected radiopharmaceuticals using Geant4/GATE simulation.Radiat Prot Dosimetry. 2025 May 27;201(7):511-521. doi: 10.1093/rpd/ncaf048. Radiat Prot Dosimetry. 2025. PMID: 40341991
-
Evaluation of absorbed and effective doses to patients from radiopharmaceuticals using the ICRP 110 reference computational phantoms and ICRP 103 formulation.Radiat Prot Dosimetry. 2013 Sep;156(2):141-59. doi: 10.1093/rpd/nct049. Epub 2013 Mar 22. Radiat Prot Dosimetry. 2013. PMID: 23525914
MeSH terms
Substances
LinkOut - more resources
Full Text Sources