Multishot diffusion-prepared magnitude-stabilized balanced steady-state free precession sequence for distortion-free diffusion imaging
- PMID: 30488979
- DOI: 10.1002/mrm.27565
Multishot diffusion-prepared magnitude-stabilized balanced steady-state free precession sequence for distortion-free diffusion imaging
Abstract
Purpose: To develop and evaluate a multishot diffusion-prepared (DP) magnitude-stabilized balanced steady-state free precession (bSSFP) diffusion imaging sequence with improved geometric fidelity.
Methods: A signal spoiler (magnitude stabilizer; MS) was implemented in a DP-bSSFP diffusion sequence. Effects of magnitude stabilizers with respect to phase errors were simulated using Bloch simulation. Phantom study was conducted to compare the apparent diffusion coefficient (ADC) accuracy and geometric reliability, quantified using target registration error (TRE), with diffusion-weighted single-shot echo-planar imaging (DW-ssEPI). Six volunteers were recruited. DW-ssEPI, DP-bSSFP with and without ECG triggering, and DP-MS-bSSFP with and without ECG triggering were acquired 10 times with b = 500 s/mm2 in a single-shot manner to evaluate magnitude variability. Diffusion trace images and diffusion tensor images were acquired using a 4-shot DP-MS-bSSFP.
Results: Simulation showed that the DP-MS-bSSFP approach is insensitive to phase errors. The DP-MS-bSSFP approach had satisfactory ADC accuracy on the phantom with <5% difference with DW-ssEPI. The mean/max TRE for DW-ssEPI was 2.31/4.29 mm and was 0.51/1.20 mm for DP-MS-bSSFP. In the repeated single-shot study, DP-bSSFP without ECG triggering had severe signal void artifacts and exhibited a nonrepeatable pattern, which can be partially mitigated by ECG triggering. Adding the MS provided stable signal magnitude across all repetitions. High-quality ADC maps and color-coded fractional anisotropy maps were generated using the 4-shot DP-MS-bSSFP. The mean/max TRE was 2.89/10.80 mm for DW-ssEPI and 0.59/1.69 mm for DP-MS-bSSFP. Good agreements of white matter ADC, cerebrospinal fluid ADC, and white matter fractional anisotropy value were observed between DP-MS-bSSFP and DW-ssEPI.
Conclusion: The proposed DP-MS-bSSFP approach provided high-quality diffusion-weighted and diffusion-tensor images with minimal geometric distortion.
Keywords: bSSFP; diffusion preparation; magnitude inconsistency; magnitude stabilizer; multishot diffusion; phase inconsistency.
© 2018 International Society for Magnetic Resonance in Medicine.
Similar articles
-
3D isotropic resolution diffusion-prepared magnitude-stabilized bSSFP imaging with high geometric fidelity at 1.5 Tesla.Med Phys. 2020 Aug;47(8):3511-3519. doi: 10.1002/mp.14195. Epub 2020 May 16. Med Phys. 2020. PMID: 32329081
-
Distortion-free diffusion MRI using an MRI-guided Tri-Cobalt 60 radiotherapy system: Sequence verification and preliminary clinical experience.Med Phys. 2017 Oct;44(10):5357-5366. doi: 10.1002/mp.12465. Epub 2017 Aug 12. Med Phys. 2017. PMID: 28692129
-
Diffusion-sensitized ophthalmic magnetic resonance imaging free of geometric distortion at 3.0 and 7.0 T: a feasibility study in healthy subjects and patients with intraocular masses.Invest Radiol. 2015 May;50(5):309-21. doi: 10.1097/RLI.0000000000000129. Invest Radiol. 2015. PMID: 25612144
-
3D distortion-free, reduced FOV diffusion-prepared gradient echo at 3 T.Magn Reson Med. 2025 Apr;93(4):1471-1483. doi: 10.1002/mrm.30357. Epub 2024 Oct 27. Magn Reson Med. 2025. PMID: 39462469 Free PMC article.
-
Diffusion-weighted MR of the brain: methodology and clinical application.Radiol Med. 2005 Mar;109(3):155-97. Radiol Med. 2005. PMID: 15775887 Review. English, Italian.
Cited by
-
Self-calibrated subspace reconstruction for multidimensional MR fingerprinting for simultaneous relaxation and diffusion quantification.Magn Reson Med. 2024 May;91(5):1978-1993. doi: 10.1002/mrm.29969. Epub 2023 Dec 15. Magn Reson Med. 2024. PMID: 38102776 Free PMC article.
-
DTI-MR fingerprinting for rapid high-resolution whole-brain T1 , T2 , proton density, ADC, and fractional anisotropy mapping.Magn Reson Med. 2024 Mar;91(3):987-1001. doi: 10.1002/mrm.29916. Epub 2023 Nov 7. Magn Reson Med. 2024. PMID: 37936313 Free PMC article.
-
Phase stabilization with motion compensated diffusion weighted imaging.Magn Reson Med. 2024 Dec;92(6):2312-2327. doi: 10.1002/mrm.30218. Epub 2024 Jul 12. Magn Reson Med. 2024. PMID: 38997801
-
Three-dimensional simultaneous brain T1 , T2 , and ADC mapping with MR Multitasking.Magn Reson Med. 2020 Jul;84(1):72-88. doi: 10.1002/mrm.28092. Epub 2019 Nov 25. Magn Reson Med. 2020. PMID: 31765496 Free PMC article.
-
Time-division multiplexing (TDM) sequence removes bias in T2 estimation and relaxation-diffusion measurements.Magn Reson Med. 2024 Dec;92(6):2506-2519. doi: 10.1002/mrm.30246. Epub 2024 Aug 13. Magn Reson Med. 2024. PMID: 39136245
MeSH terms
LinkOut - more resources
Full Text Sources