Feasibility and Variability of Automated Pupillometry Among Stroke Patients and Healthy Participants: Potential Implications for Clinical Practice
- PMID: 30489422
- DOI: 10.1097/JNN.0000000000000416
Feasibility and Variability of Automated Pupillometry Among Stroke Patients and Healthy Participants: Potential Implications for Clinical Practice
Abstract
Background: Early neurological deterioration (END) is common after stroke and represents a poor prognostic marker. Manual pupillary assessment to detect END is subjective and has poor interrater reliability. Novel methods of automated pupillometry may be more reliable and accurate. This study aims to evaluate the acceptability and feasibility of automated pupillometry in patients with acute stroke and healthy volunteers and compare its interrater reliability with that of the traditional manual method.
Methods: Automated and manual pupillary assessments were recorded between 2 independent observers alongside routine neurological observations from 12 acute stroke patients at a high risk of END. The proportion of completed measurements, adverse events, and qualitative feedback from patients and staff nurses was used to assess acceptability and feasibility of automated pupillometry. Paired automated and manual assessments were supplemented with measures from healthy volunteers to analyze measures of variability and agreement.
Results: Automated pupillometry was acceptable and safe among 12 acute stroke patients, but feasibility criteria were not attained. Interrater agreement for automated pupillometry was superior to manual assessment for measurements of pupil size, anisocoria, and pupillary light reactivity, for both patients and healthy volunteers. Substantial disparity existed in agreement between automated and manual assessments of these parameters.
Conclusions: Automated pupillometry represents an alternative to manual pupillary assessment that may have greater interrater agreement and reliability. As an optimized method of neurological assessment, it has the potential to improve detection and treatment of conditions leading to END after stroke.
Similar articles
-
Interrater Reliability of Pupillary Assessments.Neurocrit Care. 2016 Apr;24(2):251-7. doi: 10.1007/s12028-015-0182-1. Neurocrit Care. 2016. PMID: 26381281
-
Automated Pupillometry in Neurocritical Care: Research and Practice.Curr Neurol Neurosci Rep. 2019 Aug 23;19(10):71. doi: 10.1007/s11910-019-0994-z. Curr Neurol Neurosci Rep. 2019. PMID: 31440851 Review.
-
Neurological Pupil Index as an Indicator of Irreversible Cerebral Edema: A Case Series.J Neurosci Nurs. 2021 Jun 1;53(3):145-148. doi: 10.1097/JNN.0000000000000584. J Neurosci Nurs. 2021. PMID: 33782353
-
Superior reproducibility and repeatability in automated quantitative pupillometry compared to standard manual assessment, and quantitative pupillary response parameters present high reliability in critically ill cardiac patients.PLoS One. 2022 Jul 28;17(7):e0272303. doi: 10.1371/journal.pone.0272303. eCollection 2022. PLoS One. 2022. PMID: 35901103 Free PMC article.
-
A Systematic Review Assessing the Current State of Automated Pupillometry in the NeuroICU.Neurocrit Care. 2019 Aug;31(1):142-161. doi: 10.1007/s12028-018-0645-2. Neurocrit Care. 2019. PMID: 30484008
Cited by
-
Exploring the feasibility of pupillometry training and perceptions of potential use for intracranial pressure monitoring in Uganda: A mixed methods study.PLoS One. 2024 May 15;19(5):e0298619. doi: 10.1371/journal.pone.0298619. eCollection 2024. PLoS One. 2024. PMID: 38748676 Free PMC article.
-
Combat Sports as a Model for Measuring the Effects of Repeated Head Impacts on Autonomic Brain Function: A Brief Report of Pilot Data.Vision (Basel). 2023 May 4;7(2):39. doi: 10.3390/vision7020039. Vision (Basel). 2023. PMID: 37218957 Free PMC article.
-
Anisocoria After Direct Light Stimulus is Associated with Poor Outcomes Following Acute Brain Injury.Neurocrit Care. 2024 Dec;41(3):1020-1026. doi: 10.1007/s12028-024-02030-1. Epub 2024 Jun 25. Neurocrit Care. 2024. PMID: 38918339
-
Automated Pupillometry Is Able to Discriminate Patients with Acute Stroke from Healthy Subjects: An Observational, Cross-Sectional Study.Brain Sci. 2024 Jun 20;14(6):616. doi: 10.3390/brainsci14060616. Brain Sci. 2024. PMID: 38928617 Free PMC article.
-
Impact of acute intoxication on quantitative pupillometry assessment in the emergency department.J Am Coll Emerg Physicians Open. 2022 Oct 26;3(5):e12825. doi: 10.1002/emp2.12825. eCollection 2022 Oct. J Am Coll Emerg Physicians Open. 2022. PMID: 36311337 Free PMC article.
MeSH terms
LinkOut - more resources
Full Text Sources
Medical