Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Meta-Analysis
. 2018 Dec 10;11(23):2405-2411.
doi: 10.1016/j.jcin.2018.06.047.

Use of Dual-Layered Stents in Endovascular Treatment of Extracranial Stenosis of the Internal Carotid Artery: Results of a Patient-Based Meta-Analysis of 4 Clinical Studies

Affiliations
Free article
Meta-Analysis

Use of Dual-Layered Stents in Endovascular Treatment of Extracranial Stenosis of the Internal Carotid Artery: Results of a Patient-Based Meta-Analysis of 4 Clinical Studies

Eugenio Stabile et al. JACC Cardiovasc Interv. .
Free article

Abstract

Objectives: The aim of this study was to evaluate the clinical efficacy of dual-layered mesh-covered carotid stent systems (DLS) for carotid artery stenting (CAS).

Background: The need to minimize the risk for plaque debris prolapsing between stent struts following CAS has resulted in the development of DLS. Small clinical studies evaluating 2 available devices, Roadsaver and CGuard, have been recently published; none of these studies is sufficiently powered to test the role of common risk factors on the occurrence of stroke at 30 days post-CAS.

Methods: A search was performed of multiple electronic databases for studies larger than 100 cases of CAS with DLS. Four single-arm prospective studies were identified, and individual patient data were collected. The primary endpoint was the occurrence of stroke at 30 days; secondary endpoints were technical and procedural success, periprocedural stroke, and in-hospital and 30-day rates of death.

Results: The Roadsaver and CGuard stents were used in similar proportions, and technical success was achieved in all procedures (100% [n = 556]). There were 6 periprocedural strokes (1.08%; all minor). During 30-day follow-up, there was 1 death (0.17%) from myocardial infarction and 1 additional minor stroke (0.17%). The cumulative 30-day mortality rate was 0.17%, and the incidence of stroke at 30 days was 1.25%. No predictors of stroke at 30 days could be identified.

Conclusions: This meta-analysis suggests that DLS can be safely used for CAS, and their use minimizes the incremental risk related to symptomatic status and other risk factors.

Keywords: carotid artery disease; carotid artery stenting; stroke.

PubMed Disclaimer

Comment in

  • A New Milestone in Carotid Stenting?
    Mudra H, Ledwoch J. Mudra H, et al. JACC Cardiovasc Interv. 2018 Dec 10;11(23):2412-2413. doi: 10.1016/j.jcin.2018.08.010. JACC Cardiovasc Interv. 2018. PMID: 30522671 No abstract available.

MeSH terms

LinkOut - more resources