Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2019 Mar;64(3):307-312.
doi: 10.4187/respcare.06255. Epub 2018 Dec 11.

Tailoring Empirical Antimicrobial Therapy in Subjects With Ventilator-Associated Pneumonia With a 10-Hour E-Test Approach

Affiliations

Tailoring Empirical Antimicrobial Therapy in Subjects With Ventilator-Associated Pneumonia With a 10-Hour E-Test Approach

Alexandre Boyer et al. Respir Care. 2019 Mar.

Abstract

Background: In a previous study of subjects suspected of having ventilator-associated pneumonia, a rapid susceptibility testing approach by using ETEST (BioMérieux) strips directly applied to bronchoalveolar lavage samples provided valuable information at hour 24. The primary objective of this study was to assess a new direct specimen testing by using an even more-rapid E-test approach (at hour 10), which could promote an early de-escalation of the antimicrobial therapy.

Methods: Twenty-eight subjects with ventilator-associated pneumonia admitted to a medical ICU were prospectively included. In parallel with standard routine methods, E-test strips were directly applied onto agar plates seeded with bronchoalveolar lavage samples and were analyzed after 10 h of incubation. E-test results were used to identify potential drug choices by simulating clinical decision making if the microscopy results had been available at the point of care. These choices were analyzed for concordance with the narrowest adequate antimicrobial therapy according to the Minimum Inhibitory Concentrations (MICs) provided by the reference method (ie, the laboratory routine diagnostic).

Results: At hour 10, direct specimen testing was readable in 18 of 28 bronchoalveolar lavage samples (64%). Total agreement between the 10-h direct specimen testing approach and the laboratory routine diagnostic approach was 90%, with a sensitivity of 83% and a specificity of 95%, with 8% major errors and 3% very major errors. The concordance between the 2 tests was very good (kappa = 0.79). If the 10-h E-test results were taken into account, then an early de-escalation strategy would have been possible in 10 of 18 cases (55%) at hour 10.

Conclusions: This rapid susceptibility testing approach provided early (10 h) and valuable information that could lead to an early adjustment of empirical antimicrobial treatment in a ventilator-associated pneumonia setting. (ClinicalTrials.gov registration NCT01266863.).

Keywords: bronchoalveolar lavage; direct antimicrobial testing; intensive care unit; nosocomial pneumonia; rapid diagnostic; ventilator-acquired pneumonia.