Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Review
. 2019 Mar:143:6-17.
doi: 10.1016/j.steroids.2018.12.003. Epub 2018 Dec 10.

Cholesterol biosensors: A review

Affiliations
Review

Cholesterol biosensors: A review

Vinay Narwal et al. Steroids. 2019 Mar.

Abstract

Cholesterol is the most important sterol synthesized by most of the human cells majorly in the liver. It is a necessary constituent of cell membranes, it acts as a precursor for the synthesis of steroid hormones, vitamin D, and bile acids. Cholesterol is transported in plasma primarily in the form of low-density lipoproteins (LDL), the principal route for its removal from tissues to the liver is in high-density lipoproteins (HDL), followed by excretion in the bile. Cholesterol level is less than 200 mg/dL in healthy persons. 200 and 239 mg/dL is considered borderline high and 240 mg/dL and above is considered a biomarker for cardiovascular diseases, heart attack, strokes, peripheral arterial disease, type 2 diabetes and high blood pressure. Several methods are available for detection of cholesterol, among them, most are burdensome, time-consuming, require sample pre-treatment, high-cost instrumental set-up, and experienced personnel to operate. Biosensing approach overcomes these disadvantages, as these are highly specific, fast, easy, cost-effective, and highly sensitive. The review describes the various cholesterol biosensors. Cholesterol biosensors work ideally within 1 to 300 s, in pH range, 7.0-8.6, temperature 25-37 °C and cholesterol concentration range, 0.000025-700 mM, the detection limits being in the range, 0.000002-4 mM, with working potential -0.05 to 0.65 V. These biosensors measured cholesterol level in fruit juices, beverages, sera and urine samples and reused up to 200 times over a period of 15 to 50 days, while stored dry at 4 °C (Table 1). Future perspective for further improvement and commercialization of cholesterol biosensors are discussed.

Keywords: Biological materials; Cholesterol; Cholesterol biosensors; Cholesterol oxidase; Nanomaterials.

PubMed Disclaimer

Publication types