. 2019 May;33(5):761-766.
doi: 10.1038/s41433-018-0310-1. Epub 2018 Dec 14.

1-year outcomes of the Xen45 glaucoma implant

Affiliations

1-year outcomes of the Xen45 glaucoma implant

Michael Smith et al. Eye (Lond). 2019 May.

Abstract

Objectives: To describe the 12-month outcomes of the Xen45 glaucoma stent.

Methods: Non-comparative retrospective study of all cases who underwent Xen glaucoma surgery in April 2017 or earlier and completed 12 months of follow-up. The primary outcome measures were intraocular pressure (IOP) reduction and number of glaucoma medications at 12 months postoperatively. The secondary outcome measures were surgical complications and the success rate of surgery at 1 year. Success rate was defined according to the multiple IOP thresholds of 15 mmHg, 18 mmHg, and 21 mmHg with all requiring a drop of 20% and no additional glaucoma surgery. Revision or needling of the Xen conjunctival bleb was not considered to constitute a surgical failure.

Results: Sixty-eight eyes were included in the study. Mean IOP dropped from 22.1 mmHg preoperatively to 14.8 mmHg at 12 months, a 33% drop (p < 0.0001). Mean number of glaucoma medications reduced from 2.9 preoperatively to 1.1 at 12 months (p < 0.0001). In total, 54.4% of cases were back on glaucoma medications by 12 months. Success rate varied from 32.4% when defined as IOP ≤ 15 mmHg and ≥ 6 mmHg and ≥ 20% reduction without medications to 70.6% when defined as IOP ≤ 21 mmHg and ≥ 6 mmHg and ≥ 20% reduction with or without medications. Thirty cases (44.1%) required bleb needling or surgical revision.

Conclusions: The Xen45 is effective at reducing IOP and glaucoma medication use at 12 months postoperatively. Patients considering this procedure should be warned that by 12 months postoperatively there is a significant chance of requiring postoperative bleb intervention and glaucoma drops.

PubMed Disclaimer

Conflict of interest statement

All authors have received meeting sponsorship from Allergan Ophthalmology except CK. MS has received research funding from Allergan.

Figures

Fig. 1
Fig. 1
Mean IOP (mmHg) over time with 95% confidence intervals

References

    1. Vinod K, Gedde SJ, Feuer WJ, et al. Practice preferences for glaucoma surgery: a survey of the American glaucoma Society. J Glaucoma. 2017;26:687–93. doi: 10.1097/IJG.0000000000000720. - DOI - PMC - PubMed
    1. Richter GM, Coleman AM. Minimally invasive glaucoma surgery: current status and future prospects. Clin Ophthalmol. 2016;10:189–206. - PMC - PubMed
    1. Lavia C, Dallorto L, Maule M, Ceccarelli M, Fea AM. Minimally-invasive glaucoma surgeries (MIGS) for open angle glaucoma: a systematic review and meta-analysis. PLoS ONE. 2017;12:e0183142. doi: 10.1371/journal.pone.0183142. - DOI - PMC - PubMed
    1. Green W, Lind J, Sheybani A. Review of the Xen Gel Stent and InnFocus MicroShunt. Curr Opin Ophthalmol. 2018;29:162–70. doi: 10.1097/ICU.0000000000000462. - DOI - PubMed
    1. Sheybani A, Lenzhofer M, Hohensinn M, et al. Phacoemulsification combined with a new ab interno gel stent to treat open-angle glaucoma: pilot study. J Cataract Refract Surg. 2015;41:1905–9. doi: 10.1016/j.jcrs.2015.01.019. - DOI - PubMed

MeSH terms