Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2019 Apr;126(4):552-564.
doi: 10.1016/j.ophtha.2018.11.016. Epub 2018 Dec 13.

Using a Deep Learning Algorithm and Integrated Gradients Explanation to Assist Grading for Diabetic Retinopathy

Affiliations
Free article

Using a Deep Learning Algorithm and Integrated Gradients Explanation to Assist Grading for Diabetic Retinopathy

Rory Sayres et al. Ophthalmology. 2019 Apr.
Free article

Abstract

Purpose: To understand the impact of deep learning diabetic retinopathy (DR) algorithms on physician readers in computer-assisted settings.

Design: Evaluation of diagnostic technology.

Participants: One thousand seven hundred ninety-six retinal fundus images from 1612 diabetic patients.

Methods: Ten ophthalmologists (5 general ophthalmologists, 4 retina specialists, 1 retina fellow) read images for DR severity based on the International Clinical Diabetic Retinopathy disease severity scale in each of 3 conditions: unassisted, grades only, or grades plus heatmap. Grades-only assistance comprised a histogram of DR predictions (grades) from a trained deep-learning model. For grades plus heatmap, we additionally showed explanatory heatmaps.

Main outcome measures: For each experiment arm, we computed sensitivity and specificity of each reader and the algorithm for different levels of DR severity against an adjudicated reference standard. We also measured accuracy (exact 5-class level agreement and Cohen's quadratically weighted κ), reader-reported confidence (5-point Likert scale), and grading time.

Results: Readers graded more accurately with model assistance than without for the grades-only condition (P < 0.001). Grades plus heatmaps improved accuracy for patients with DR (P < 0.001), but reduced accuracy for patients without DR (P = 0.006). Both forms of assistance increased readers' sensitivity moderate-or-worse DR: unassisted: mean, 79.4% [95% confidence interval (CI), 72.3%-86.5%]; grades only: mean, 87.5% [95% CI, 85.1%-89.9%]; grades plus heatmap: mean, 88.7% [95% CI, 84.9%-92.5%] without a corresponding drop in specificity (unassisted: mean, 96.6% [95% CI, 95.9%-97.4%]; grades only: mean, 96.1% [95% CI, 95.5%-96.7%]; grades plus heatmap: mean, 95.5% [95% CI, 94.8%-96.1%]). Algorithmic assistance increased the accuracy of retina specialists above that of the unassisted reader or model alone; and increased grading confidence and grading time across all readers. For most cases, grades plus heatmap was only as effective as grades only. Over the course of the experiment, grading time decreased across all conditions, although most sharply for grades plus heatmap.

Conclusions: Deep learning algorithms can improve the accuracy of, and confidence in, DR diagnosis in an assisted read setting. They also may increase grading time, although these effects may be ameliorated with experience.

PubMed Disclaimer

Publication types